Caution – Toa N-8000MI User Manual
Page 10
10
7.1.2. Caution when installing the unit
Perforated panel
Equipment rack
N-8000MI
Do not stack up 3 units or more. If 2 or more units are mounted in the Equipment rack, be sure to mount the
perforated panel of 1 U size (PF-013B) or more above and below every 2 units.
Step 1. Install the rack-mounting bracket to the N-8000MI.
Step 2. Mount the N-8000MI on the Equipment rack.
Étape 1. Installez la patte de montage en bâti sur l’unité N-8000MI.
Étape 2. Montez l’unité N-8000MI en bâti.
7.1.3. N-8000MI mounting
Montage du N-8000MI
Do not block the ventilation slots in the unit’s cover. Doing so
may cause heat to build up inside the unit and result in fire.
CAUTION
Rack mounting screw 5 x 12
with plain washer (accessory)
Rack mounting bracket
(accessory)
Tapping screw 3 x 8
(accessory)
Patte de montage
(accessoire)
Vis de montage en bâti 5 x 12
avec rondelle simple (accessoire)
Vis-taraud 3 x 8
(accessoire)
N-8000MI
1
2