7.1.2. Caution when installing the unit

Perforated panel

Equipment rack

N-8000MI

Do not stack up 3 units or more. If 2 or more units are mounted in the Equipment rack, be sure to mount the

perforated panel of 1 U size (PF-013B) or more above and below every 2 units.

Step 1. Install the rack-mounting bracket to the N-8000MI.

Step 2. Mount the N-8000MI on the Equipment rack.

Étape 1. Installez la patte de montage en bâti sur l’unité N-8000MI.

Étape 2. Montez l’unité N-8000MI en bâti.

7.1.3. N-8000MI mounting

Montage du N-8000MI

Do not block the ventilation slots in the unit’s cover. Doing so

may cause heat to build up inside the unit and result in fire.

CAUTION

Rack mounting screw 5 x 12

with plain washer (accessory)

Rack mounting bracket

(accessory)

Tapping screw 3 x 8

(accessory)

Patte de montage

(accessoire)

Vis de montage en bâti 5 x 12

avec rondelle simple (accessoire)

Vis-taraud 3 x 8

(accessoire)

N-8000MI