[Connecting to the PBx's OD trunk]

Connect the PBX's transmitting line to the unit's RX terminal, and the PBX's receiving line to the TX terminal.

Also connect the PBX's M (Mouth) line to the unit's E (Ear) terminal, and the PBX's E line to the M terminal.

CH1

M

TX

RX

C

E

M

TX

RX

C

E

CH2

N-8000MI's PBX interface terminal

To PBX OD trunk's transmitting line (T2)

To PBX's ground point
To PBX OD trunk's M and E lines

To PBX OD trunk's receiving line (R2)

2 channels

To PBX OD trunk's transmitting line (T1)

To PBX's ground point
To PBX OD trunk's M and E lines

To PBX OD trunk's receiving line (R1)

[Connecting to the Intercom's Tie-Line Unit]

Connect the intercom's transmitting line to the unit's RX terminal, and the receiving line to the TX terminal.

CH1

M

TX

RX

C

E

M

TX

RX

C

E

CH2

N-8000MI's PBX interface terminal

To Intercom's transmitting

line (T1)

To Intercom's receiving

line (R1)

To Intercom's transmitting

line (T2)

To Intercom's receiving

line (R2)

2 channels

Note

Do not ground the Functional earth terminal (No. 6 on p. 8) in this PBX connection.