Caution – Toa VX-200PS ER User Manual
Page 11
11
• Strip the cable end long enough (30 mm ± 5 mm) to
be fully clamped. Otherwise, its outer jacket
prevents the cable conductor from being tightly
secured, causing poor contact.
Correct
Incorrect
[Attaching the insulating sheet]
To prevent the battery cable from being shorted to the rear panel due to misconnection, attach the supplied
insulating sheet in place following the procedures below.
Step 1. Remove the screw indicated by the arrow.
Step 2. Put the supplied insulating sheet over the
battery terminals, and fix it with the removed
screw.
24V
MAX150A
BATTERY POWER IN
WARNING
Take special care to prevent the battery from
being shorted by misconnection of the battery
cable. If the short occurs, the unit may fail.
Insulating sheet
VX-2000DS
Attention label
Step 1. Allow more than 10 seconds to elapse after removing the power cord from the VX-2000DS' rear-
mounted AC inlet.
Step 2. Insert the positive battery cable into the VX-2000DS' rear-mounted BATTERY POWER IN positive
terminal from the bottom side of connector, then tighten the terminal screw with a flat screwdriver.
Note
Never connect the negative cable first to avoid battery short-circuit that occurs if the positive cable
should contact the unit chassis or equipment rack.
Step 3. Connect the negative battery cable to the negative terminal in the same manner as Step 2.
[Connecting the Battery]
1
2
VX-2000DS
24V
MAX150A
BATTERY POWER IN
Note correct polarity (positive and negative orientation) when
connecting the power supply cord. Reversed polarity connections will
cause damage to the system.
CAUTION