12

Rack

VX-2000DS

Thermistor

Batteries

[Installing a thermistor]

The thermistor located on the VX-2000DS' rear panel is designed to compensate for temperature changes
when charging the battery. It should be left hanging in the space around the battery.

Step 1. Confirm that battery power is not in use by means of the VX-2000DS' front-mounted BATTERY

POWER LED, which is unlit in this case.

Step 2. Loosen the VX-2000DS' BATTERY POWER IN negative terminal screw, then pull out the negative

battery cable.
Notes
• Never remove the positive cable first to avoid battery short-circuit that occurs if the positive cable

should contact the unit chassis or equipment rack.

• Insulate the exposed end of the removed cable with insulating tape to avoid shorting to the other

cable.

Step 3. Remove the positive battery cable from the positive terminal in the same manner as Step 2.

Note
Insulate the exposed end of removed cable with insulating tape to avoid shorting to the other cable.