Toa VX-200PS ER User Manual

Page 6

Advertising
background image

6

2.2. VX-200PS Power Supply Unit

1

[Rear]

2

3

4

1. Power indicator [POWER]

These indicators (one for each channel) light
green when DC power is output.

2. DC output terminal 1, 2 [PS OUT]

Connects to the PS IN terminals of the VX-
2000DS Emergency Power Supply.

3. AC fuse 1, 2

Type: 250 V, T3.15 A L

4. AC inlet

Using the supplied power cord, connect this
AC line receptacle to a power source of 230 V
AC, 50/60 Hz.

Note
The VX-200PS Power Supply unit is designed for exclusive use with the VX-2000 system, SX-2000 system,
and VM-3000 system.

Up to 3 VX-200PS Power Supply units can be mounted in the V-2000PF Power Supply Frame. The VX-
200PS unit has 2 DC output channels, and up to 3 units (6 ch) can be connected to one VX-2000DS
Emergency Power Supply. Use the VX-200PS in the number suited to the required total system power.

2.3. VX-2000PF Power Supply Frame

[VX-2000PF Components]

This unit is comprised of the following components. For the component assembly, refer to p. 7.

1. Front panel .................... 1
2. Side panel ..................... 2

The VX-2000PF permits the VX-200PS Power Supply to be mounted in an equipment rack.
Up to 3 VX-200PS units can be installed in the VX-2000PF. Refer to p. 8 for the VX-200PS mounting
procedure.

3. Chassis (VX-200PS guide rails pre-mounted) ..............1
4. Fixing bracket* ..............................................................1

[Front]

[Top]

2

2

3

1

4

* The Fixing bracket is not supplied

with the previous VX-2000PF.
(Refer to p. 9.)

Advertising