Professional Surround Sound Tuning Kit

NOTE: It is important to have the microphone in the primary listening position for
the first measurement.

Press the Measure button. The Audyssey™ test signal will play a series of
10 “chirps” through each channel.

B. Additional Position Measurements

Move the microphone to another listening position and press the Measure
button again. Repeat the process for all listening positions in the room.

You will need to measure a minimum of three positions before you can
continue. The recommendation is to measure a minimum of eight positions
for typical rooms.

Click the forward arrow to finish the measurement process and continue to
the “Detection Results” screen, which displays the results of the
measurements.

Click the forward arrow to proceed to the “Target Sound Options” screen.

4. Target Sound Options

Choose which of the Audyssey™ target curves you want to use by selecting
the radio button next to the curve:

For small to medium rooms (up to 2500 cu. ft.), choose the High
Frequency Roll Off 1
curve.

For medium to large rooms (up to 5000 cu. ft.), choose the High
Frequency Roll Off 2
curve.

For rooms larger than 5000 cu. ft., choose the SMPTE 202M
curve.

The Midrange Compensation option (selected by default) is used to adjust
the balance between on-axis and reflected sound in the crossover region. It
is recommended that you leave this box checked. You can return to this
screen later and change your setting if you prefer.

Click the forward arrow to calculate your correction curves and proceed to
the “Save Results” screen.

5. Save Results

A. Transfer the MultEQ

®

XT Filters

Click Transfer to Crestron to temporarily store the filters so you can listen
to them. This process may take several minutes.

B. MultEQ

®

Pro On/Off Demo

You can now use the MultEQ On and Off buttons to demo the MultEQ

®

XT

filters.

Operations Guide – DOC. 6565C