Triner Scale TS60KD-1010 User Manual

Page 9

Advertising
background image

Assembly

Guide Triner

TS60KD-1010

Platform

Scale

9


8. Adjust all ramps as needed.


MAKE SURE that gaps are maintained between the two weighing decks and
between the ramps and the weighing decks.


A pry bar will be helpful for final positioning of the ramps.

9. Using a hammer drill and a ½” diameter bit, drill the holes and install the ½”

anchor bolts through the foot retaining plates and the ramps and tightly secure.

10. Position the indicator stand in a suitable location next to the scale.


11. Attach the digital indicator to the indicator stand using the screws provided.


12. Connect the two interface cables to the quick connects coming out of the digital

indicator.

13. Using a hammer drill and a ½” diameter bit, drill the holes and install the ½”

anchor bolts in the base of the indicator stand.

14. Plug the digital indicator into a standard 110 VAC power source and the

indicator will power up.

15. If the scale does not read zero, press the ZERO key on the indicator.


16. The system is ready for use.


Notes:
It is recommended that the two cables coming from the scale platforms to the digital
indicator be protected in some fashion (conduit etc.)

For information on how to operate the digital indicator, see the indicator manual
provided.


Advertising