10

29

Error cliché EPROM

Cliché EPROM not present, defective, or incorrectly installed. IC- and socket markings do not agree or
IC contact legs make no contact.
Permanent Error code 10 and machine blocks.

Check components (all pins good contact, correct position, is it the right component?)

If a new cliché EPROM was just installed and the error is:
10 21, 10 22 or 10 29 indicates the EPROM or its contents do not match this type of machine.

10

2x

Error cliché EPROM

Cliché EPROM not present, defective, or incorrectly installed. IC- and socket markings do not agree or
IC contact legs make no contact.
Permanent Error code 10 and machine blocks.

Check components (all pins good contact, correct position, is it the right component?)

If a new cliché EPROM was just installed and the error is:
10 21, 10 22 or 10 29 indicates the EPROM or its contents do not match this type of machine.

11

hardware error memory µP - CPU

Hardware error in processor memory. Machine blocks with permanent error code displayed.

technicain:
replacement of CPU // mainboard

12

read / write error RAM

First beep phase is long. Machine cannot write into or read from RAM. Machine blocks with permanent
error code 12 displayed.

technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board

13

Memory differences registers R1 - R4

Memory differences in Registers R1 - R4 (postal register) could not be corrected. Permanent error
code 13 displayed.

technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board

14

write error RAM

No RAM could be written

technicain:
1. Replace memory components and observe machine; If error repeats itself:
2. Replace MC board

diagnostic-
code

subcode1
subcode2

diagnostic message

remedy

ISS international service support
email: [email protected]

created : 20.11.2007 19:31 Uhr

page 6