NATURAL GAS CONNECTION – T

WIN

E

AGLES

T

EPPANYAKI

G

RIDDLE

• The regulator supplied is set for 4” water column and is for use with Natural gas only.

• The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply

piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

• The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual

manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less

than 1/2 psi.

• A typical natural gas installation is shown below. Make sure the factory supplied regulator is used and installed

with the arrow mark on the regulator pointing in the same direction as the gas flow going from the supply line to the

Teppanyaki Griddle. The regulator is preinstalled onto the end of the Manifold. Use only the regulator provided as

original equipment with your Teppanyaki Griddle. Use only pipe sealants that are approved for use with natural and

LP gases. An installer supplied gas shutoff valve must be installed in an accessible place.

Caution: Provide adequate ventilation holes in the enclosure for safety purposes in the event of a gas

leak.

5