USL, Inc. JSD-80 Instruction Manual

Page 9

3rd Edition. February, 2006

Section 2: Installation

2.1 System Hardware Mounting

and Grounding

The JSD-80 is designed to mount in a stan-

dard 19" rack, and is two standard rack

spaces (3-1/2") high. We recommend vented

panels above and below whenever space

permits. Mounting the unit immediately

above a major heat-producing component

(such as a power amplifi er) is not recom-

mended. The JSD-80 includes a three-prong

grounding plug and a three-wire power

cord to accommodate a safe ground path

from the chassis to the electrical system

ground. Defeating this ground by removing

the ground prong is not recommended.

2.2 System Cooling and

Ventilation

Important

Care should be taken to insure the JSD-80

has adequate ventilation for cooling during

operation. It is recommended that one rack

space below the JSD-80 is left open to allow

outside air circulation through the unit. A

ventilation panel, USL, Inc. part number

VP-1, is recommended for projection booths

where the normal ambient temperature

exceeds specified equipment operating

temperatures listed in the safety section

of this manual. Also, it is recommended

that equipment with no more than a nine-

inch depth be mounted directly above the

JSD-80 to insure adequate airfl ow through

the unit’s rear ventillation slots.