The vacuum pump of the BVC may contaminated due to operation. The protective

filter with a pore size of 0.2 µm does not avoid safely a contamination of the vacuum

pump in all cases.

Also in case of a defect of the filter or operation of the BVC without filter pathogenic

germs (e. g., bacteria, viruses, prions, fungi) may enter the pump.

A decontamination of the vacuum pump is possible in the following ways:

- Gassing of the interior.

- Disassambling the pump parts and insertion of the parts in a disinfectant solution

or by autoclaving of the contaminated parts.

Decontamination of the vacuum pump

only BVC control / G and BVC professional / G

The applicability of the decontamination method and the selection of the ap-

propriate disinfectant have to be ensured by the user.