Cooling water minimization

Coolant valve 24 V= ................................................... 676013
-

compact design, designed for a high number of operations
at short intervals

-

solenoid systems with splash protection

-

conductance optimised for applications with rotary evapora-
tor and exhaust waste vapour condenser

-

with integrated Y-connector to connect an in-line valve

Vacuum management

Vacuum management system VMS Module A
(consisting of a connecting cable to the controller, a country
specific adapter cable to hook-up the pump and a mains cable)
VMS Module A CEE .................................................. 676001
VMS Module A UK
..................................................... 676002
VMS Module A US
..................................................... 676004
-

high condensate resistance of the pump, also suitable for
interval operation due to sufficient operation time of the pump

-

energy and water consumption are reduced to a minimum

-

vacuum control according to requirements - a principle for
work stations for one or multiple users

-

Standby for coolant and vacuum

Coolant valve 230 V~, 50-60 Hz ................................. 676010
(for use with the VMS)
Y-socket-plug connector ........................................... 676015
(to connect several components to the pin socket of the CVC
2

II

, e. g. for simultaneous operation of in-line valve and VMS)

Accessories of controller

In-line valve VV 6C 24 V= .......................................... 674091
(PVDF/PTFE, small flange NW 16, hose nozzle NW 6/10)
In-line valve VV 6 24 V= ............................................ 674090
(PP/FPM, small flange NW 16, hose nozzle NW 6/10)
In-line valve VV 15C 24 V= ........................................ 674110
(PVDF/PTFE, small flange NW 16)
In-line valve VV 15 24 V= ........................................... 674115
(PVDF/PTFE, small flange NW 25)

Installation and accessories

Vacuum distribution

VACUU•LAN

®

manual flow control module

VCL 01 ...................................................................... 677106
VACUU•LAN

®

shut off / manual flow control module

VCL 02 ....................................................................... 677107
VACUU•LAN

®

automatic control module

VCL 10 ....................................................................... 677108
VACUU•LAN

®

manual flow control/

automatic control module VCL 11 ................... ........677109

The VACUU•LAN

®

modules allow process orientated, flexible

and cost effective connections according to the requirements:
One vacuum pump for multiple work stations.

On this page we offer only a small selection of VACUU•LAN

®

options. Please refer for further information.

VCL 01

VCL 10

VCL 02

VCL 11