Cooper-Atkins 93025 User Manual

Page 4

Advertising
background image

4

5

35025 BATTERY REPLACEMENT

1) Turn battery doorknob counter-clockwise until

rotation stops. The arrow on battery door knob will

point towards unlock icon.

2) Pull battery doorknob to remove battery door

assembly. Remove batteries.

3) Referring to battery polarity drawing on rear label,

install (2) AAA alkaline batteries as shown.

4) To install battery door assembly, ensure that battery

doorknob is turned fully counter-clockwise and arrow

on battery door is pointed towards unlock icon. Push

inward on battery door assembly until battery doorknob

is seated against housing. Rotate battery doorknob

clockwise until rotation stops. The arrow on battery

doorknob will point towards lock icon.

TURN COUNTER-CLOCKWISE TO UNLOCK

TURN CLOCKWISE TO LOCK

SYSCAL 35025 THERMOCOUPLE

OPERATING INSTRUCTIONS

5) The resolution default setting is tenth degree. To

change resolution to whole degree, press and hold

key and then press key.

6) Press key to turn on backlight. When pressed,

the backlight will remain on for 5 seconds and

automatically turn off.

NOTE: USE OF BACKLIGHT WILL

SIGNIFICANTLY DECREASE BATTERY

LIFE DUE TO INCREASED POWER

REQUIRED FOR BACKLIGHT OPERATION

7) The instrument has a “HOLD” feature to capture the

current temperature reading on the display. To activate

the hold feature, press and release the key. The

current temperature reading will flash on the display

and the hold icon will appear at top of display. Press

the key again to return to STANDARD

TEMPERATURE MODE.

Press to turn instrument ON or OFF. When

used in combination with SHIFT key, enables

or disables AUTO-OFF feature.

Press to select FAHRENHEIT or CELSIUS

temperature scale. When used in combination

with SHIFT key, selects tenth degree or whole

degree resolution.

Press to “FREEZE” current temperature

reading on display. SHIFT function provides

secondary user settings with other keys as

noted.

Press to turn on BACKLIGHT for viewing

temperatures in low lighting conditions.

When pressed, BACKLIGHT will remain on

for 5 seconds.

OPERATION:

1) Observing correct polarity, insert thermocouple probe

into connector on top of instrument.

2) Press key to turn instrument on.

3) Default temperature scale is Fahrenheit. To change

temperature scale, press key. (NOTE: Display

will toggle between “F” and “C” icons on right
side of display with each press of the key).

4) The instrument has an AUTO-OFF feature that will turn

off unit after 10 minutes of non-keypad activity to

conserve battery life. To manually turn instrument off,

press and hold key momentarily. To disable

AUTO-OFF feature, press and hold key and then

press key. (NOTE: “AUTO” icon at top of display

will appear when AUTO-OFF feature is active).

(0.1/1)

BATTERY REPLACEMENT:

Advertising