Warning, Trouble- shooting, Preventive maintenance schedule – Coleman 5075 Series User Manual

Page 11

Advertising
background image

ENGLISH

11

Continued

TROUBLE-

SHOOTING

WARNING

Never attempt to service heater while it is plugged in, connected to propane
supply, operating or hot. Severe burns and electrical shock can occur.

SYMPTOM

POSSIBLE CAUSE

REMEDY

Fan does not turn

No electrical power to heater

Check voltage to electrical outlet.

when heater is

If voltage is good, check heater

plugged in.

power cord for breaks.

Fan blades bent

Replace fan. See Replacing Fan,
Page 13.

Defective motor

Replace motor. See Replacing Motor,

page 12.

Heater will not

User did not follow prepara-

Repeat preparation and opera-

ignite.

tion or operation instruc-

tion instructions. See Preparation,

tions properly

pages 6 & 7 and Operation, pages 7,
8 & 9.

No spark at electrode. To test
for spark, follow step 9 un-
der Replacing Electrode,
page 13. If you see spark at
ignitor, have heater serviced
by qualified service person.
If no spark seen:
A) Loose or disconnected

A) Check ignitor wire. Tighten

ignitor wire

or reattach loose ignitor wire.
See page 5 for ignitor
wire location.

B) Wrong spark gap

B) Set gap between ignitor electrode
and target plate to .20" (0.5 cm).

C) Piezo ignitor loose

C) Tighten piezo ignitor to base
of heater.

D) Bad electrode

D) Replace electrode. See Replacing

Electrode, page 13.

E) Bad piezo ignitor

E) Replace ignitor.

F) Bad electronic module

F) Replace electronic module.

Heater shuts down

High surrounding air tem-

This can happen when running

while running.

perature causing thermal

heater in temperatures above

limit device to shut down

85°F (29°C). Run heater in cooler

heater.

temperatures.

Restricted air flow

Check heater inlet and outlet.
Remove any obstructions.

Damaged fan

Replace fan. See Replacing Fan,
page 13.

Excessive dust or debris in

Clean heater. See Maintenance,

surrounding area

pages 9 & 10.

WARNING

Use only in areas
free of high dust
content.

ITEM

HOW OFTEN

HOW TO

Fan

Clean every 500 hours of

See Fan, page 10

operation or as needed.

Electrode

Clean and regap every 500

See Electrode, page 10

hours of operation or replace
as needed.