Measure center of window on sash and sill.

I^Make a small pencil mark to indicate spot. Raise

sash. Position bottom track on sill lining up with
center mark.*3

If storm windows present interference, fasten a

2" wide wood strip to window’s sill. Thickness of
wood strip should equal height of storm window’s
ledge. By inserting wood strip, you will create a level
surface for unit installation.

I

Screw track onto sill using 3

short

screws.

I

Slide wing panels from unit mounting kit into

kit’s upper guide, with drain holes on bottom of wing
panels facing outward for condensation run-off.

I

Slip lower portion of connected wing panels

into bottom track now on sill.

I

Stretch wing panels out on both sides to meet

window frame.

Lower window sash onto upper guide.

I

With sash firmly down upon upper guide,

make a pencil mark on lowered window sash
through center hole on upper guide.

I

Drill hole at mark and insert provided

short

screw. DO NOT completely tighten screw.

I

Move accordion fold? aside to reveal holes on

sides of wing panels. Use previous marking tech­

nique (Step 11) and drill holes in pencil marked
spots. Secure wing panels in sash tracks by insert­
ing

long

screws in drilled holes and tightening.

Make pencil marks through all holes in bottom

track while track is positioned on window sill.

I

Remove track and drill three holes in window

sill at marked spots.

I

Remove paper backing from narrow seal strip

in unit accessory mounting kit and fasten strip to top
of casing, aligning with pre-drilled holes in casing.
Fasten top channel to top of casing using 4 screws,
inserted upwards from inside casing.

*3

If your window width exceeds our maximum recommen­

dation, then your unit will require additional support.