For Wood Framing:

Provide a wooden framing

support for fastening casing in wall opening.

I

With a pencil, mark location of screw holes to

be drilled through each side of casing to fasten it in

wall opening.

NOTE:

If existing holes in casing will

suffice for attachment to framing, additional drilled

holes may not be required. Be sure to seal any

fcunused holes in this area. Make sure unit is level.*2

I Fasten casing in wall opening using masonry

or wood screws, anchors, mounting angles or
expansion shields as needed (depending on type
of construction frame used).

I

Recheck pitch of unit for level installation.*3

I

Using

2

people, lift chassis and re-insert into

casing installed in wall opening. See steps 28
through 32 under Window Installation. Follow same
procedures for Through-the-Wall Installation.

CAUTION:

Coil fins on chassis are sharp and

chassis is heavy.

I

Finish exterior and interior of wall opening

surrounding installed unit. Grouting, caulking or
flashing may be used for sealing and weather­
proofing-exterior. *4

Plug in unit and slide excess cord into cord

storage opening.

If needed, drill 2 or 3 screw holes (spaced as

needed, depending on construction frame used) for
each side of casing.

I

Paint or apply silicone on edges of drilled holes

to protect against corrosion.

*2

Front

Of

unit casing must project at least

'k

inch into room

to assure proper fit of grille casing on units front.

*3 When casing is installed, using proper installation steps,

unit is properly pitched towards the outdoors to allow for
condensation run-off. An Accessory External Drain Kit is
available to route excess unit condensaron away from build­
ing exterior. If unit is installed where condensate drainage will

drip onto pedestn'ans or neighboring properTes, contact your
independent Carrier Dealer, or call

1

-800-CARRIER to order

the External Drain Kit.

*4

Be sure to weatherproof exterior area around the wall-

installed unit, and finish surrounding interior walls.