TORQUE SELECT

[ 1

MIN.

LIMIT

, (WHITE)

p n n n n n n n

r)

pmnnnnf^

|j

^ MAX.

LIMIT

(BLACK)

FURNACE

SIZE

MIN

SETTING

MAX

SETTING

58SSB060

3

7

58SSB080

3

10

Fig. 2 — Torque Setting

7. Slide ECM blower assembly into furnace and tighten

screws to secure blower assembly to the blower shelf.

8. Reinstall furnace control box on bottom side of

blower shelf.

9. Connect electrical leads from furnace control pre­

viously used as blower speed selector taps to
numbered connector which is panel mounted on the
left side of the interface control box. Black lead to
position 1, red lead to position 2, white lead to posi­

tion C.

10. Double-check to make sure main power disconnect

is off.

In steps 11 through 14, the 115-v power leads to ECM

blower icit connects in parallel with furnace 115-v power
supply. To do this:

11. Remove cover of auxiliary junction box.

12. Remove strain relief securing the power leads in place

on the auxiliary J-box.

13. Route power leads from ECM blower kit through

opening in back of auxiliary junction box. Dis­

connect black lead from furnace control at door
switch, and connect black lead with 3/16-in. piggy­
back quick-connect from ECM blower kit in its place.
Then reconnect black lead from furnace control to
3/16-in. male quick-connect provided on piggyback
connector. Remove wire connecting white lead of

furnace control to line voltage common line. Connect
white wire from ECM blower kit and reinstall wire
nut.
Make sure all power leads are secured in place using

the strain relief provided with this kit.
Reinstall cover to auxiliary junction box.
Disconnect all existing thermostat leads from the

furnace control board if applicable.
Connect W, R, and C from terminal block TB3

labeled, HEAT, on interface circuit board located on
front of blower housing to their respective thermostat
connections on furnace control board, labeled (W,

R, C) using field-supplied thermostat wire cut 6 in.

in length and stripped 1 /4 in. on each end. See Fig. 3.
Install thermostat following instructions included
with outdoor section. For single zone applications,
route 6-conductor thermostat wire into furnace

through one of the knock-outs in the cabinet. Multi­
zone applications require only 3-conductor wire.
Slide electrical noise suppressor provided, over
thermostat wire before making electrical connections

(see Fig. 3) at blower assembly.
NOTE; For electrical interference and noise, refer to
38EV,QV outdoor section Installation, Start-Up and
Service Instructions.

14.

15.

16.

17.

18.

19.

PARKER INDOOR

THERMOSTAT TERMINALS

AUXILIARY
JUNCTION BOX

LOW-VOLTAGE
TERMINAL BLOCK

ELECTRICAL

NOISE

SUPPRESSOR

ECM BLOWER KIT
INTERFACE BOARD-

FIELD LOW-VOLTAGE WIRING

■ FIELD HIGH-VOLTAGE WIRING

FACTORY LOW-VOLTAGE WIRING

---------------------- 1

THERMOSTAT LINE

(SEE FIG. 4a OR FIG. 4b
FOR CONNECTIONS)

INTERFACE CABLE

► SINGLE

PHASE

VAR. SPEED
CONDENSING

UNIT

NOTE: If any of the original wire as supplied must be replaced, use same type or equivalent wire.

Fig. 3 — Field High- and Low-Voltage Wiring Diagram