310736-401 rev. a, Fig. 6 — schematic wiring diagram, 5/>s – Carrier 58SSB User Manual

Page 4: Isisr

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

CONNECTION DIAGRAM

MOTOR

INTERFACE

CONTROLLER

BOX

PCBl

PCB2

, INTERNAL FUSE

ши (WHEN USED)

lA-TRANSFORHER, 120VAC/24VAC

2D-RELAY, INDUCER MOTOR DPST-N.O.

2E-RELAY, HEATING BLOHER (HER) SPST-K.C.

2F-RELAY, COOLING BLOHER (CFR) DPDT

3A-H0T0R, INDUCER
5F-VALVE, GAS (REDUNDANT)

6CI-B0ARD. P.C. (FURNACE CONTROL)

6C2-B0AR0, P.C. (INDUCER CONTROL)

•6C3-L0CK0UT MODULE

6F-GENERAT0R, SPARK (SOLID STATEl

6H-SHITCH. PILOT FLAME SENSING SPOT (740A)

7H1-SHITCH, LIMIT SPST-N.C.
7H2-SHITCH, DRAFT SAFEGUARD(SPST-N.C.) MANUAL RESET

7H3-SHITCH, AUXILIARY LIMIT(SPST-N.C.) MANUAL RESET

(HHEH USED)

7P-PRESSURE SHITCK, H.O.

7V-SHITCH, FLOH SENSING SPDT

9G-SHITCH, BLOHER DOOR INTERLOCK SPST-li.f.

FACTORY HIRING (120VAC)

FACTORY HIRING(24VAC)

—— FIELD HIRING (120VAC)

- CONDUCTORS ON 6C1 (FURNACE CONTROL BOARD)

CONDUCTORS OH 6C2 (INDUCER CONTROL BOARD)

@ SCREH TERMINAL FOR FIELD HIRING

t=3 1/4 INCH QUICK CONNECT TERMINALS

10B1-CONNECT0R. EDGE (FURNACE CONTROL BOARD)

1OB2-CONNECT0R, EDGE (INDUCER CONTROL B0ARD-7CKT.)

10B3-COHNECTOR, EDGE (INDUCER CONTROL B0ARD-2CKT.)

10B4-CONNECT0R. PILOT

10B5-FACT0RY TEST POINTS (NOT FOR FIELD USE)

1DB6-CONNECTOR, BLOHER MOTOR (PL3 ON PCB2)

IIB-FUSE, IN LINE 2AMP (HHEN USED)

11C-LIHK, FUSIBLE (OVER TEMPERATURE) (1 REQD. ON UPFLOH t

3 REQD. OH DOHNFLOH/KORIZONTAL FURNACE

llE-GROUHDj EQUIPMENT

HTRl-MOTOR (ECM) BLOHER

PCBI-P.C. BOARD (ECM BLOHERCONTROL )

PCB2-P.C. BOARD (INTERFACE)
T-3-THERMISTOR
TP)-TEST POINT

TRAN-24VAC TRANSFORMER

SEV-SOLENOID EXPANSION VALV:

SCHEMATIC (NAT'L a PROP)

5/>S

О

solid

state

time

delay

relay

------------------- ---- -------------------------------------------

1

-isisr*

_____________ I

I

c@=

T2-INTERNALLY CONNECTED TO EQUIPMENT GROUND SPARK GENERATOR (6F)
MOUNTING SCREhS.

RELAY (2E) CONTACTS ARE NORMALLY CLOSED UNTIL 120VAC IS APPLIED

TO FURNACE.

IF ANY OF Tl

IT MUST BE I...... .................. . -

BLOHER MOTOR (HTR-1) HAS A THERMAL OVERLOAD SWITCH.

BLOHER MOTOR (MTR-1) FACTORY SPEED ADJUSTMENTS ARE FOR AVERAGE

CONDITIONS. SEE ECM BLOHER KIT INSTALLATION INSTRUCTIONS

FOR DETAILS OH OPTIMUM SPEED SELECTION.

USE COPPER WIRE ONLY BETWEEN THE DISCONNECT SWITCH AND THE UNIT.

SYMBOLS ARE AH ELECTRICAL REPRESENTATION ONLY.

PRESSURE SWITCH (7P) IS USED FOR PROPANE ONLY.

FUSIBLE LINK USAGE, 1 REQD. OH UPFLOH & 3 REQD. ON DOHHFLOK/

HORIZONTAL FURNACE.

LOCKOUT MODULE (6C3) IS USED FOR PROPANE OR 100« SHUTOFF

NATURAL GAS.

2AMP FUSE IN SECONDARY OF TRANSFORMER FOR CANADIAN UNITS ONLY.

310736-401 Rev. A

Fig. 6 — Schematic Wiring Diagram