ELECTRICAL DATA, SOME

UNIT

MODEL

50ME016

50ME024

50ME028

50ME030

50ME034

'0

50ME040

... .

----

-

V/PH/HZ

VOLTAGE

COMPRESSOR

NO. 1

COMPRESSOR

NO. 2

OUTDOOR

FAN MOTOR

PI A

INDOOR

FAN

luinmo

RANGE

CB

MTA

CB

MTA

Min

Max

RLA

LRA

RLA

LRA

No. 1

No. 2

No. 3

Hp

FLA

200/3/60

180

229

63 6

266

89 0*

6 2

66

5 0

16 2

230/3/60

207

264

57 2

266

80 0*

---

62

60

50

13 2

460/3/60

414

528

28 6

120

40 0

62

30

5 0

6 6

575/3/60

518

660

22.8

96

32.0

6.2

2.4

5.0

5.6

200/3/60

180

229

44 4

170

63 0*

44.4

170

62 0

6 2

6 6

7 5

24 0

230/3/60

207

264

40.0

170

56 0

40 0

170

56 0

62

60

7 5

22 0

460/3/60

414

528

199

77

27.8

19 9

77

27 8

6 2

30

7 5

11 0

575/3/60

518

660

15.7

62

22.0

15.7

62

22.0

6.2

2.4

7,5

9.0

200/3/60

180

229

63 6

266

89 0

44 4

170

62 0

62

6 6

10.0

29 5

230/3/60

207

264

57 2

266

80 0

40 0

170

56 0

6 2

60

100

26 0

460/3/60

414

528

28 6

120

40 0

19 9

77

27 8

6 2

30

100

130

575/3/60

518

660

22,0

96

32 0

157

62

22 0

62

24

100

10.5

200/3/60

180

229

63 6

266

89 0

63 6

266

89 0

62

66

100

29 6

230/3/60

207

264

57 2

266

80 0

57 2

266

80 0

6 2

60

100

26 0

460/3/60

414

528

28 6

120

41 0

28 6

120

41 0

62

30

100

13 0

575/3/60

518

660

22 8

96

33 0

22 8

228

33 0

62

2.4

100

10.5

200/3/60

180

229

63 6

266

89 0

63 6

266

89 0

6 2

6 6

6 6

150
20 0

46.2
61 0

230/3/60

207

264

57 2

266

80 0

57 2

266

80 0

62

60

60

150

20 0

46 2

59 4

460/3/60

414

528

28 6

120

40 0

28 6

120

40 0

62

30

3 0

150

20 0

21 0
26 6

575/3/60

518

660

22 8

96

32 0

22 8

96

32 0

6 2

24

2.4

150
20 0

^16 0

21 3

200/3/60

180

229

80 0

332

1120

80.0

332

112 0

6 2

6 6

6 6

150
20 0

46 2
61 0

230/3/60

207

264

77 0

300

106 0

77 0

300

106 0

62

6 0

6 6

150

20 0

46 2

59 4

460/3/60

414

582

39 3

150

54 0

39 3

150

54 0

62

30

3 0

150
20 0

21 0
26 6

575/3/60

518

660

31 4

120

44 0

31 4

120

44 0

6 2

24

24

150
20 0

160

21 3

POWER

SUPPLY

Min

Max

Ckt

Fuse

Amps

Amps

109 8

125

98 9

110

49 5

60

39.6

£5

138 0

150

124 2

150

61 9

70

49.2

60

168 9

200

151 7

175

75 8

90

60 2

70

188 0

200

168 9

200

84 5

100

67 3

90

2108

225

224 6

250

188 9

200

200 9

250

94 5

100

100 5

125

75.6

90

80 6

100

247 7

300

261 5

300

233 5

300

245 5

300

1167

150

122 7

150

95 0

125

100 0

125

CBMTA —

Circuit Breaker Must Trip Amps

FLA

— Full Load Amps

LRA

— Locked Rotor Amps

RLA

— Rated Load Amps

*Unit has 2 mechanically interlocked circuit breakers Values are for each

NOTE Outdoor air fan motor is a 200/230-1-60 motor on all units