Fig. 2 6, Accessory mounting rack – Carrier 38QB User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

I'-O" (305 mm)
GRAVEL APRON

Г-И" (584mm) DIAM

marker

tape

(HIDDEN)

б" (152 mm)

THICK

CONCRETE MOUNTING PAD FOR 38QB0I5

2 - 6 " (762mm) DIAM

Fig. 2

6

" (152 mm)

THICK

CONCRETE MOUNTING PAD FOR 38QB0I8-060

- Accessory Mounting Rack

condition (Table 2). For requirements beyond 50 ft,
obtain information from loeal Carrier distributor.

If 1-1/8in. tubing is used (38QB042,048,060),

braze it to the accessory 1-1/8 x 3/4-in. suction
connection adapter (Carrier Part No. 28AU900061)
or to a correctly sized field-supplied adapter, then

make Compatible Fitting connections. Isolate inter­

connecting tubing from framing and ductwork or
where tubing runs thru stud spaces, enelosed ceilings
or pipe chases. Use isolation type hangers. Fig. 3,
since rigid fastening transmits pulsations to struc­
ture creating objectionable sound.

Fig. 3 — Refrigerant Line Hangers

Table 2 — Installation Data (Fig. 1)

UNIT 38QB

015

018

024

030

036

042

048

060

OPERATING WEIGHT

(l|))

140

179

185

187

, 197

229

240

252

DIMENSIONS

Diameter (ft-in.)

(mm)

Height (ft-in.)

(mm)

REFRIGERANT CONNECTIONS

Suction (ODF)

Liquid (ODF)

REFRIGERANT LINES

Suction (ODF)

Liquid (ODF)

‘May use 7/8-in (22 22-mm) accessory tubing package with slight capacity loss See Table 3

3