Table 3 — accessories – Carrier 38QB User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 3 — Accessories

PART NO.

DESCRIPTION

UNIT 38QB

99TZ90040106

Low-Voltage Control — Honeywell Thermostat HH07AT171 and

Thermostat Subbase HH93AZ173 — (Automatic Changeover)

99TZ90041106

Low-Voltage Control — Honeywell Thermostat HH07AT171 and

Thermostat Subbase HH93AZ175 — (Manual Changeover)

All

38QB90002106

Service Sentry (Six HN65CT004)

99TZ90029101

Honeywell — Manual Changeover. 2-Stage Heating, 1-Stage Cooling

28AU90006112

Twelve 3/4- x 1-1/8 in. Connection Adapters

042-060

38R090008106

Bi-Flow Heat Pump Filter Drier

(Six

KH45LD077)

HN65DE026*

Supplemental Heat Relay-
(Service Parts)__________

- (Required with 2 Outdoor Thermostats )

38HQ900002

Outdoor Thermostat (Six 38HQ900011)

All

38CQ900172

0ptimizerControlOutdoorThermostat(Six38CO900161 ref HH22AG110)

38RQ900091

Optimizer II Control Assembly (Use with HH2AG1 lOoutdoorthermostat.)

38QB90001106

Heat Pump Rack (Six)

015-018

38QF90000106

Heat Pump Rack (Six)

024-060

38HQ90014106

Optimizer III (Six 38HQ900141)

38QB90003106

Solid-State Time Guard II (24-volt)

All

HC95DD120*

Start Capacitor

015

HC95DD12V

Start Capacitor

018

HC95DD058*

Start Capacitor

024,030

HC95DD088*

Start Capacitor

036

HN61HB515*

Relay

015,018

HN61HB496*

Relay

024,030,036

38EB660002*

TUBING

PACKAGE

38LS958151
38LS958201
38LS958251
38LS958301
38LS958351
38LS958401
38LS958501

38LS934151
38LS934201
38LS934251
38LS934301
38LS934351
38LS934401
38LS934501

38LS978151
38LS978201
38LS978251
38LS978301
38LS978351
38LS978401
38LS978501

Wire Bundle for Start Capacitor and Relay

015-036

TUBING

*Available thru Carrier Service Parts
tSuction line is insulated and has 90° bend
tFor 5/8-in (15 9-mm) evaporator connection, cut off 3/4-in (19 05-mm) belled end

‘‘Capacity reduction may occur when 7/8-in (22 22-mm) accessory tubing is used on 38QB042,048,060

A capacity reduction will result if accessory tub­

ing is used in 38QB042 systems. For example, when
a 25-ft (7.6-m) 7/8-in. (22-mm) accessory package is
used, there is a capacity reduction of 1-1/2percent.

When other than 25 ft (7.6 m) of interconnecting

tubing is used, follow special requirements described

in Refrigerant Charging. Do not use less than 10 ft
(3 m) of interconnecting tubing. Do not cut 5/ 16-in.
(7.9-mm) or 1/4-in. (6.4-mm) liquid line due to

swage at ends. Do not cut 7/8-in. (22.22-mm)

suction line. Bend or coil to fit.

Do not use damaged or contaminated tubing.

Always evacuate or purge evaporator coil and

tubing system (use field-supplied refrigerant, not
unit refrigerant).

When making tubing connections, be sure to

provide clearance at unit for electrical connections.