Installation, Eh 5 – Sears 2500 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Electric Disconnect

□ B

instaii motor bracket on left side. Make sure bracket is

firmly seated (Fig. 6).

Media

Wheel

Large

Diameter

Wire

Support

Small Diameter

Wire Support.

Position Media

Wheel Shaft

Under Dimples

Flexing

Outward.

EH

C

Remove media wheel wire supports from reservoir. In­

sert large diameter wire support on left side of reservoir and small
diameter wire support on right side of reservoir. Place media wheel
in wire supports with gear on left side of reservoir. (Flex wire sup­
port outward to capture media wheel shaft under dimples.) Fig. 7.

Unit is now converted to a left side motor.

installation

(on sheet metal plenum duct)

NOTE: Figures 8 & 9 show humidifier installation on supply air
plenum for illustration purposes only. If more convienient,
humidifier may be mounted on return air plenum. If humidifier is
installed on the return air plenum, the flexible hose (round collar

opening) is connected to the supply air plenum.

FIBER PLENUM DUCTS

NOTE: The mounting screws supplied are for standard installa­

tion on sheet metal plenum ducts, if you have fiber plenum ducts,

install the humidifier and components with thru-bolts, nuts, and
washers (not supplied). If necessary, reinforce the humidifier

mounting area on fiber ducts with sheet metal and provide addi­

tional bracing as required to support the weight of the humidifier
and water. (This fiber duct installation hardware is not supplied
and must be purchased from your local hardware store.)

1

Mark a level line on plenum. Hold stiffener against the ple­

num with bottom edge on level line and flanges toward you. Mark

the location of all holes Including large rectangular opening in

center on plenum (Fig. 8).

□ 2

Drill or punch a large hole in one corner of rectangle.

This will allow you to insert the tin snips or metal saw.

CAUTION: BE SURE NOT TO DRILL OR CUT INTO AIR

CONDITIONING COIL OR TUBING.

EH

4

Drill the remaining holes marked on the plenum with a

1/8" drill bit.

EH 5

Mount the stiffener with the flanges toward you using

the four corner mounting holes. Do not use Hole “A". Make sure
stiffener is flush with the plenum. Seal around edge with caulking

if necessary (Fig. 8).

EH

G

Hang the humidifier case on the mounting tabs. The

tabs may have to be bent out slightly to mount the case. Secure
the case to the stiffener with a sheet metal screw in hole “A".

NOTE: It is very important that the case is secured. If the

case is not attached with the screw, it could be dropped and

damaged during routine maintenance.

EH

7

Position collar at selected location. Mark center open­

ing and (5) holes. Cut out center opening and drill (5) 1/8" holes.

Advertising