8

Attach collar and flexible hose to plenum. If additional

flexible hose is required, an eight foot length is available through
the parts department, order 281152-05. Before tightening screws,
insert damper between collar and plenum (Fig. 10). It should be
open for humidifier operation.

FIG. 10

Damper Blade
(Slide shut
before using air

conditioning.

Slide open at

start of heating

season.)

C] 9 Connect the flexible hose as shown using clamp pro­
vided. Do not allow flexible tube to come within 3" of furnace flue

pipe because of flue pipes extreme heat. If hose is under stress
(pulling), it may be necessary to drill 2 holes in humidifier collar

for screws. This will prevent clamp from slipping off (Fig. 11).

require overflow protection. The overflow is in the bottom of the
humidifier reservoir (Fig. 12). Use 1/2" inside diameter rubber or
plastic tubing to connect to nearby floor drain. (Tubing not sup­
plied. Overflow tubing is available at your local hardware store.)

11

Install media wheel and reservoir tray In humidifier case

and engage latch on right hand side to valve body inlet stem.

installation

WATER SUPPLY

1

Water for the humidifier must be taken from a nearby

cold water line.Turn off the water supply. Drain by opening a fau­
cet at a lower level of the line.

□ 2

Position the saddle valve on the water line as close to

the humidifier as possible. You have been supplied with 10 foet of

1/4" plastic tubing.

SPECIAL NOTE: When measuring the distance from the
saddle valve location to the humidifier, keep in mind that the
tubing must be supported; therefore, it must mn along ceiling
and walls. Measure along the path the tubing will follow.

□ 3

Back out the piercing pin by turning the 'T' handle

counter clockwise and then clamp the saddle valve body securely

on the water line with rubber gasket positioned as shown (Fig.

13). On galvanized or copper pipe over 5/8", first drill a 5/32" hole.

CAUTION: For safety, use a hand drill or grounded electric drill.

□ 4

Turn handle clockwise until it has pierced the water

line and valve is completely closed (Fig. 13).

□ 5

Partially uncoil the tubing. Slide the brass compres­

sion nut over the tubing. The threads in the nut must face the

tubing end. Place the brass compression sleeve as shown in Fig.

13. Slip brass insert into end of tubing.

0 Insert the tubing end into the saddle valve at threaded

stem “A” (Fig. 13) as far as it will go. Thread the brass compres­
sion nut onto the valve, then tighten gently with a wrench. Take

care not to overtighten the nut.

Brass Compression Sleeve

^

- Brass Insert

Brass

Compression Nut

Rubber Gasket

(Stem Up)

MOUNTING SADDLE VALVE

Advertising