EH 7

Unwind the rest of the tubing. Take care not to kink it.

Run the tubing along flat surfaces to the humidifier. Support the

tubing as needed to avoid contact with furnace.

8

Close previously opened faucet. Turn on main water

supply. Place a pail under the end of the tubing. Open the saddle
valve. Flush the line. Make sure there are no leaks along the line
or at the valve. Turn valve off.

EH

9 Remove the quick disconnect socket, brass compres­

sion nut, and brass sleeve from hardware bag (Fig. 14). With water
supply tubing cut to the proper length, slide the brass compres­
sion nut and sleeve over the tubing as described in Step 5, Page

6. Slip brass insert into the end of tubing.

QUICK DISCONNECT

ASSEMBLY

Quick Disconnect

Socket

1/4" Plastic

Water Supply

Tubing

10

Insert the tubing end into the quick disconnect socket

as far as it will go and hold it there, thread the brass compression

nut onto the quick disconnect socket, then tighten using two

wrenches, one to hold quick disconnect socket and one to tighten

nut. DO NOT over tighten nut.

n 11

Connect the quick disconnect socket to the plug on the

valve body (Fig. 16).

To connect, pull back sleeve, push socket onto plug, release

sleeve.

To disconnect, pull back sleeve, unlocking quick disconnect and
sealing water supply line, separate from plug.

FIG. 15

\

\

Quick

Disconnect

Plug

Sleeve

'Plug

■Humidifier

12

Turn on water supply at saddle valve. Check water level.

Water should be 3/8" below top of overflow compartment wall

(Fig. 17). If adjustment is necessary, disconnect water supply tub­

ing, and remove float assembly (Fig. 18). See instructions on bot­

tom of float. To raise water level, turn float clockwise. To lower

water level, turn float counterclockwise.

□ 13

Attach front panel. Be sure lip at bottom of front panel

is inside lip at front edge of humidifier case.