INSTALLATION

LOCATING YOUR

COOLER

Your cooler has been shipped ready for installa­
tion in a down discharge position. It can easily
be changed to side discharge. The cooler must

be securely fastened to a frame or pad mount A
roof kit is available from Sears,

A duct must be attached to the cooler outlet. The
duct must be the same size as the cooler outlet

Sudden duct size changes will decrease the out­
put of your cooler.

The cooler installation must comply with local
codes. If you are not fully qualified to install a
cooler, get professional help.

Figure 1 shows locations lor your cooler. Be
sure the intake louvers are clear of obstructions
and are accessable for removal. Do not locate
the cooler near vent pipes, chimneys, or exhaust
where odors or fumes may be drawn into the
house.The two drain holes on the cooler bottom
must be clear to allow overflow or drain access.

FIGURE

ROOF KIT MOUNT

SIDE DISCHARGE INTO HALT

DOWN DISCHARGE

CONNECT TO HOUSE DUCTING

W m m Q

iOK (FIGURE 2)

The wiring box is inside the cooler cabinet. The
electrical

supply

must

be

connected

to

the

cooler power leads inside the box after the
cooler in installed. The wiring box Is factory
Installed for coolers used in the down air outlet

position.

... IF..YOU...INSTALL THE COOLER IN THE SIDE

AIR DISCHARGE POSITION THE WIRING BOX

MUST 8E MOVED. SEE PAGE 5.

...............

SHUT

.AT THE ELECTRI CAL

SERVICE

BOX

BEFORE

STARTING

WIRING,