instaliatiori Step 9

Electrical Requirements

^WARNING

To reduce the risk of electric shock, your garage

door opener has a grounding type plug with a third

grounding pin. This plug will

only

fit into a grounding

type outlet.

If the plug doesn't fit into the outlet you have,

contact a qualified electrician to install the proper

outlet.

To avoid installation difficulties,

do not run the opener at this time.

To prevent electrocution or fire,

installation

and wiring must be in compliance with local
electrical and building codes.

Do

NOT

use an extension cord, 2-wire adapter,

or change the plug in any way to make it fit

your outlet.

Wrong

If permanent wiring is required by your

local

code, refer to the following procedure:

WARNING

To prevent electrocution,

remove power from

the garage door opener

and

from the circuit

you plan to use for the permanent connection.

To make a permanent connection through the

7/8" diameter hole in the top of the opener

(according to local code):

• Remove the opener cover screws and set the

cover aside.

• Remove the attached 3-prong cord.

• Connect the black (line) wire to the screw on the

brass terminal; the white (neutral) wire to the

screw on the silver terminal; and the ground wire

to the green ground screw.

The opener must

be

grounded.

Reinstall the cover.

To avoid installation difficulties,

do not run the opener at this time.