0 -0-(p---(^-(r, Heating system, Cooling system a caution – Sears 1F86-382 User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

JUMPER

WIRE

0-0 -0-(p---(^-(R^^

For 2-wire Heat only,
attach to RH and W

Fan

Heating

Relay

System

THERMOSTAT

SYSTEM

Hot

120 VAC

Neutral

TRANSFORMER

Figure 2.Typical wiring diagram for

heat only, 3-wire, single transformer systems

JUMPER

WIRE

Figure 3. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Figure 5. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

JUMPER

WIRE

JUMPER

WIRE

Reversing

Compressor

Fan

Valve*

Contactor

Relay

THERMOSTAT

SYSTEM

Reversing valve is energized when the

system switch is in the COOL position

Hot

120 VAC

'Jeutral

TRANSFORMER

Figure 6. Typical wiring diagram for heat pump

with reversing valve energized in COOL

RED jumper wire (provided with thermostat) must be
connected between thermostat RH and RC terminals
for proper thermostat operation with this system

JUMPER

WIRE

thermostat

“ < w

--------------

Y W SYSTEM

Cooling

Fan

Heating

System

Relay

System

Hot

120 VAC

'Jeutral

transformer

Figure 4. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

JUMPER

WIRE

JUMPER

WIRE

Reversing

Compressor

Fan

Valve*

Contactor

Relay

THERMOSTAT

SYSTEM

Reversing valve is energized when the

system switch is in the HEAT position

Hot

120 VAC

vleutral

TRANSFORMER

Figure 7. Typical wiring diagram for heat pump

with reversing valve energized in HEAT

t The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a year

with fresh premium brand alkaline batteries.

Heating System

1. Move SYSTEM switch to HEAT position. If the heating system

has a standing pilot, be sure to light it.

2. Press to adjust thermostat setting above room tempera­

ture. The heating system should begin to operate.

3. Press (2) to adjust temperature setting below room tem­

perature. The heating system should stop operating.

Cooling System

A CAUTION

To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate the
cooling system.

Move SYSTEM switch to COOL position.

Press to adjust thermostat setting below room tempera­

ture. The blower should come on immediately on high
speed, followed by cold air circulation

Press to adjust temperature setting above room tem­

perature. The cooling system should stop operating.