The thermostat buttons and switches (see fig. 8), The display, Configuration menu – Sears 1F86-382 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

OPERATION

Before you begin using your thermostat, you should be familiar

with its features and with the display and the location and
operation of the thermostat buttons. Your thermostat consists of
two parts: the thermostat cover and the base. To remove the

cover, pull it straight out from the base. To replace the cover, line
up the cover with the base and press until the cover snaps onto
the base.

The Thermostat Buttons and Switches

(see fig. 8)

© Raises temperature setting.

Lowers temperature setting.

0 FAN switch

(ON, AUTO).

0 SYSTEM switch

(COOL, OFF, HEAT).

The Display

(0

Flame icon (¿))

is displayed when the SYSTEM switch

IS in

the HEAT position. Snowflake icon (*)is displayed (non­
flashing) when the SYSTEM switch is in the COOL posi­
tion. Snowflake is displayed (flashing) if the thermostat is

in lockout mode to prevent the compressor from cycling

too quickly.

(0 Displays current temperature.

(0

Displays "FILTER" when the system has run for the se­

lected filter time period as a reminder to change or clean
your air filter.

(0

Displays set point temperature (this is blank when SYS­

TEM switch is in the OFF position).

(0

Displays "BATTERY" and "LO" in the current temperature

location when the 2 "AA" batteries are low and should be
replaced.

F

r n

~ i n c n n

l U и и

l U u u

BATTERY i Ò

FILTER t *

8 ) ( 5

7 )

( 6

Figure 8. Thermostat display, buttons, and switches

CONFIGURATION MENU

The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require­

ments.

Move SYSTEM switch to the OFF position, then press and

at the same time to enter the configuration menu. The

display will show the first item in the configuration menu.

The configuration menu chart below summarizes the configura­
tion options. An explanation of each option follows.

Press and to change to the next menu item. To exit the

menu, move the SYSTEM switch to HEAT or COOL. If no keys
are pressed within fifteen minutes, the thermostat will exit the
configuration menu.

Configuration Menu

Step

Press

Button(s)

Displayed (Factory Default)

Press © or © to select:

COMMENTS

1

Set SYSTEM

switch to OFF

SYSTEM switch must be OFF to configure thermostat
options

2

0>andQ

Ф

(FA)

SL

Select FA or SL (Fast or Slow) heating cycle rate

3

©and©

d-L

(ON)

OFF

Select display backlight OFF or ON

4

©and©

FILTER

(000)

0 to 1950 hours

(in 50 hour increments)

Select Filter replacement run time

5

©and©

LOG

(OFF)

ON

Select Compressor lockout OFF or ON

6

©and©

0 HI

(0)

4 LOto

4 HI

Select temperature display adjustment higher or lower

7

©and©

(F)

C

Select temperature display to F or C

8

Set SYSTEM

switch to HEAT

or COOL

Returns to normal operation

' Press Q and Q to advance to next item

Advertising