PREPARATION

Adequate courrterspace must be provided for the unit.

The area should be easy to reach and be lighted with

natural light during the day.

See t he first page for cutout dimensions. Mark the cutout

on the counter. Use a hand or saber saw to make the cut.

ELECTRICAL CONNECTIONS

Call your Electric Company and ask which codes apply

In your area. If there are no codes, you must follow the
NATIONAL ELECTRICAL COOES, ANSI/NFPA NO. 70-
Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

The counter unit cord has a three prong plug and must
be plugged into a properly grounded three hole outlet.
The outlet must be In a standard 120 Volt, 60 Hertz AC
household circuit.

Improper grounding can spark ignition on models so

equipped.

A

Do

not

under

any

circumstances

cut or remove the grounding prong
from the counter unit cord. Failure
to provide proper polarization may

cause shock and fire hazard.

If you do not have a grounded three hole outlet, have an
electrician change your old outlet or install a new one.

To temporarily use a properly polarized and grounded
two hole outlet until a grounded three hole outlet can be

installed, a grounding adapter plug may be used. Have
an electrician test the outlet to be sure it meets require­
ments.

PLUG WITH GROUND PRONG

PROPERLY POLARIZED AND

GROUNDED RECEPTACLE

POLARIZED RECEPTACLE

PROPERLY GROUNDED

METAL EYELET

GROUND

PREFERRED METHOD

RECEPTACLE

PLATE

MOUNTING

SCREW

Fig. 2

TEMPORARY METHOD

GAS CONNECTIONS

Cal I your gas suppi ler and ask which codes apply In your

area. If there are no codes, you must follow the NA­
TIONAL FUEL GAS CODE, ANSI/Z223.Latest Edition.

You can get a copy by writing:

American Gas Association

1515 Wilson Boulevard

Arlington (Rosslyn), VA 22209

Know where your main gas shut off valve Is.

Shutoff gas supply before removing an old range. Leave
it off until hookup of new counter unit is finished.

See figures on this page for rigid and flexible pipe

hookups. Some local codes do not allow the use of
copper gas pipe. If flexible connectors are alio wed,

a new A.G.A. certified flexible connector is rec­

ommended. Never reuse an old connector when
Installing a new unit. A manual shut-off valve, for

the purpose of turning on or shutting off the gas

supply to the appliance, must be installed in the
gas supply line at an accessible location in the
cabinet beiow the counter unit.

We recommend that you use 1/2” gas supply line.

1” FROM BACKWALL

i

T

f—l21/2"-H

FROM CUTOUT
CENTERLINE

LOCATION OF GAS SUPPLY LINE

FIG.3