Troubleshooting, Manual advance regeneration check – Sears 625.34855 User Manual

Page 23

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION 5

SERVICE TECH INFORMATION

5A.

TROUBLESHOOTING

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration
flow rates, and other controller functions. Always
make the initial checks, and the manual
initiated diagnostics.

NOTES: The face plate display must show a steady
time (not flashing). If an Error code shows, first
press the #1 SELECT button to enter the diagnostic
display.

1.

Press the ON/OFF-HOLD button and hold in

for 3 seconds. RECHARGE NOW and FILL
begin to flash as the softener enters the fill
cycle of regeneration. When FILL is on steady,
remove the brinewell cover and, using a
flashlight, observe fill water entering the tank.

a. If water does not enter the tank, look for an

obstructed nozzle, venturi, fill flow plug, brine
tubing, or brine valve riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FILL (flow to salt storage tank) 0.3 (1.1 liters)
BRINING

\

.19 (.7 liters)

BRINE RINSE (

.12 (.45 liters)

BACKWASH

i(flow to drain) 2.0 (7.6 liters)

FAST RINSE

y

____________ 2.0 (7.6 liters)

2.

After observing fill, press the ON/OFF-HOLD

button to move the softener into brining. A
slow flow of water to the drain will begin.
Verify brine draw from the brine tank by
shining a flashlight into the brinewell and
observing a noticeable drop in the liquid level.

NOTE: Be sure a salt bridge is not preventing
water with salt contact.

a. If the softener does not draw brine* *

• nozzle and/or venturi dirty or defective.
• nozzle and venturi not seated properly on

gasket.

• restricted drain (check drain fitting and

hose).

• defective nozzle and venturi seal.
• other inner valve defect (rotor seal, rotor &

disc, wave washer, etc.).

NOTE: If water system pressure is low, an
elevated drain hose may cause back pressure,
stopping brine draw.

3.

Again press ON/OFF-HOLD to move the

softener into backwash. Look for a fast flow of

water from the drain hose.

a. An obstructed flow indicates a plugged top

distributor, backwash flow plug, or drain hose.

4.

Press ON/OFF-HOLD to move the softener

into fast rinse. Again look for a fast drain flow.
Allow the softener to rinse for a few minutes to
flush out any brine that may remain in the resin
tank from the brining cycle test.

5.

To return the softener to service, press

ON/OFF-HOLD.

75