SERVICE TECH INFORMATION

5C. WATER FLOW THROUGH THE SOFTENER VALVE

FAST RINSE CYCLE

ROTOR & DISC

During FAST RINSE, the rotor & disc is positioned so water flow enters the
resin tank through the top distributor, and exits through the bottom
distributor, to the drain.

The electronic timer again energizes the motor to return the valve to service.
As the valve rotates, the position switch lever drops to open the circuit. The
valve remains positioned in service until the electronic timer initiates the
next regeneration.