- HOW TO INSTALL YOUR HOME DRINKING WATER SYSTEM -

MAKE REMAINING RO CONNECTIONS - continued

C. CONNECT TUBING TO WATER SUPPLY

Use the tubing insert, ferrule and nut, at the water

supply saddle valve, to fasten the remaining 1/4”
tubing (marked “WATER SUPPLY”). Tighten the

nut with a wrench.

B. CONNECT TUBING, FAUCET TO DRAIN TUB­
ING CONNECTOR

Looking at FIG, 7 and page 16, run the 3/8” x 27"

tubing from the RO faucet, to the connector at the

adapter you installed in the sink drain pipe. Cut this

tubing as needed to route in as straight of a run as

possible without dips, loops, low spots or kinks.
Be sure the end of the tubing is cut square, then

push the end into the connector until it stops (about

11/16"). Pull on the tubing to be sure it is held se­

curely.

STEP 5

— SANITIZING, PRESSURE TESTING, PLACING IN "SERVICE”

D. Fasten the faucet base and electronic box lead-

wire connectors together, routing where dry, and

out of the way.

A. DO THE SANITIZING PROCEDURES, PAGE

15. THEN, CONTINUE WITH STEP B.

B, Double check all tubing connections to be sure

they are tightened.

C. Open the house main water supply valve and

the supply saddle valve (turn handle fully out). Open
the tank shutoff valve. . .see below.

D. In about 4 hours, pressure will start to build in

continued on next oaae