- CARE OF YOUR HOME DRINKING WATER SYSTEM -

RO CARE GUIDE

MODEL RO 2000 WITH MONITOR

IMPORTANT: BEFORE DOING THE FOLLOWING MAINTENANCE, BE SURE TO RELIEVE
PRESSURE AND ALLOW AIR TO ENTER THE TANK, STEPS 1, 2 AND 3, PAGE 12.

1. Replace the prefilter cartridge and postfilter when the amber ‘FILT’ light begins to flash

while taking product water from the RO faucet. Clean or replace the flow control and screen,

and replace the batteries in the electronic control box.

2.

Replace the RO membrane cartridge when the amber “RO" light begins to flash while tak­

ing product water from the RO faucet. Clean or replace the flow control and screen.

NOTES;

a.

If slow making of product water occurs before an amber light begins to flash,

replace the prefilter cartridge. If production rate does not improve, then replace the postfil­

ter and RO membrane,

b.

If product water flow from the RO faucet is slow, do the steps

referred to in the IMPORTANT note above.

OTHER TROUBLESHOOTING

PROBLEM

CAUSE

CORRECTION

Chorine

taste andlor odor

in

the RO product water

The ppm of chlorine in your water supply

exceeds maximum limits, and has de­

stroyed the RO membrane.

Ifthewatersupplycontainsmorethan2.0ppmof

chlorine,

addi­

tional filtering of the watersupply tothe RO is needed. Correct
this condition before doing maintenance on the RO system.

Replace the RO membrane cartridge, flow control, screen, pre­

filter, postfilter, and batteries in the electronic box.

The prefilter is no longer removing chlo­

rine from the water supply.

Other

taste andlor odor

Postfilter expended.

Replace thepostfilter. litaste and odor persists, replace thepre-

filter, RO membrane cartridge, flow control, screen, and batter­

ies in the electronic box.

RO membrane cartridge expended.

Contamination in product water storage.

Use sanitizing procedures. Then replace the postfilter.

High

total

dissolved

solids

(TDS) In product water

WatersupplytotheRO system not with in

specifications.

Increase wate r pressu re, precond iti on th e water, etc., as n eed ed

to conform before doing maintenance on the RO system.

RO membrane cartridge expended.

Replace the RO membrane cartridge, flow control, screen, pre­

filter, postfiiter, and batteries in the electronic box.

Slow product water flow from

the RO faucet

Vacuu m created in storag e area for prod­

uct water.

Open the vacuum relief valve and allow the tank to fill with air.

See page 12.

Water leaking from faucet air­

gap hole

Drain side of faucet airgap (3/8" tubing)

plugged, restricted, or incorrectly con­
nected to drain point.

Inspect and eliminate restriction or plug. Refer to installation

instructions for proper drain connection.

Indicator

lights,

on

faucet

base,

not working

Faucet base leadwire not connected to

electronic box leadwire.

Connect

Battery pack not connected to electronic
box.

Batteries installed incorrectly, or ex­
pended.

Observe

orientationmarkingsontheholderandinstallcorrectly.

Replace batteries if old.

Leadwires or connectors damaged.

Inspect and repair or replace as needed.

Tubing Connection at Drain Adapter: Cut the end of

the tubing square and push into the fitting as far as

possible (11/16"}. Pull on the tubing to be sure it is
held firmly in place.

To Disconnect Tubing:

Push the tubing inward to de­

press the fitting

collet.

Hold the collet in while pulling

the tubing out.

tubing

collet

1 6