Section 3 step by step guides to install, 3 step by step guides to install 7, Fig. 9 – Sears 625.34823 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION

3 STEP BY STEP GUIDES TO INSTALL

7.

CONNECT THE FILTER
{Refer to your plan drawing on page 7, and to page
8

.)

- SOLDER COPPER OR CPVC PIPE

Read the important note in step 6. Then put the

3.

gaskets, tubes and nuts shown in FIG. 9, or the

flexible connectors* (Sears kit, page 8) onto the

inlet-outlet adaptors or bypass valve.

NOTE: The nuts, tubes and gaskets are for 3/4 in.
plumbing connection. For 1 in. connection, do not
use the nuts, tubes and gaskets. From your local
hardware store, buy 2 sweat adaptors (1 in. female

thread x 1 in. sweat) and plumb directly to the in­

stallation adaptors or bypass valve. Threads on the
installation adaptors and bypass valve are 1 in. pipe

thread.

Measure, cut and put all pipe and fittings

D> together up to the main water pipe, or to the

bypass valve(s) you installed in step 6.

When all piping fits together good, solder (or

C.

solvent cement CPVC) all joints following tips

on page 20.

FIG. 9

INLET-OUTLET FITTINGS

Gasket

inlet and Outlet

Adaptors

Tube Nul

/ Nu(

Tube

Gasket

Bypass

Valve '

INLET

▲ CAUTION: BEFORE SOLDERING, DISCONNECT

NUTS (FIG. 9) AT THE ADAPTORS OR BYPASS

VALVE. THIS WILL STOP THE HEAT, CAUSED

BY THE SOLDERING, FROM GOING INTO THE

FILTER VALVE AND MELTING PLASTIC PARTS.
After plumbing cools, put nuts back on and tighten.

THREADED PIPE

Read the important note in step 6. Then

3.

measure, cut, th read and put together pipe and

fittings from the inlet-outlet adaptors (or bypass
valve) up to the main water pipe, or to the
bypass valves installed in step 6.

NOTE: For 1” connection, use a 1” fitting directly

on the installation adaptors or bypass valve. Threads
on the adaptors or bypass valve are 1 in. male pipe.

b

Include union fittings or flexible connectors*

■ (Sears kit, page 8).

Cut pipe lengths exact for correct aligning, and to

C. prevent stress on the filter valve. Use pipe dope

or teflon tape on all outside threads.

CAUTION: BE VERY CAREFUL WHEN PUTTING
PIPE FITTINGS ONTO THE PLASTIC THREADS

OF THE INLET-OUTLET ADAPTORS, OR THE

BYPASS VALVE. DO NOT CROSS-THREAD. DO
NOT OVERTIGHTEN.

‘Flexible connectors are not allowed in all areas. Check your local plumbing codes.

8. Fasten or support all piping (use pipe hangers)

to keep the weight of the plumbing off of the

filter inlet and outlet fittings, so they do not leak
or break.

11