SECTION 3 STEP BY STEP GUIDES TO INSTALL

ELECTRIC POWER OUTLET FOR YOUR
FILTER

The filter works on 24 volt, 60 Hz electric power. The
included transformer changes standard 120 volt AC

house power to 24 volts. You must plug the transformer
Into a 120 volt outlet only. Be sure the outlet is always
"live” so spmeone cannot turn it off by mistake.

^ « FASTEN THE POWER CABLE AND PLUG IN

THE TRANSFORMER

Looking at FIG. 14, fasten the 2 power cable lugs (1
under each screw) to the transformer as shown.

Tighten both screws, then plug the transformer into
the outlet.

NOTE; When you plug in the transformer, 12:00 AM

and SU begin to flash in the face plate display,

^ Д SANITIZING THE WATER FILTER

' Care is taken at the factory to keep your filter

clean and sanitary. Materials used to make the filter
will not infect or contaminate your water supply, and
will not cause bacteria to form and grow. However, if
sanitizing is needed, do the following.

FIG. 14

CONNECTING TRANSFORMER

Transformer

\\/^\ Power Cable (Hook either lead

' under either transformer terminal.)

_ Press and hold button

^__

until RCHG begins to flash in the face plate

on the face plate

AM

ncHG 12:00

SU

display, starting a backwash.
After 5 to 10 minutes, press
button H] again to start fast

______ _

rinse. Wait about 1 minute. THEN TURN OFF WATER

TO THE FILTER AT THE MAIN SUPPLY VALVE.

Press button d] once more to return the valve to

service.

ij Carefully remove the large plastic clip at the

filter valve inlet (FIG. 7, page 10) and pull the
adaptor out.

NOTE: If bypass valve. Item No. 42/65-3437 is install­
ed, or if plumbing is too rigid to move, also disconnect

the outlet side and move the filter away from plumbing.

C.

Put 1 teaspoon (0.1 ounce) of calcium
hypochlorite into the valve inlet as far as

possible.

NOTE: You can buy calcium hypochlorite in tablet or

granular form using trade names such as Perchloron
and HTH.

d.

e.

f.

Carefully reconnect the plumbing.

Turn on the water supply.

Open the nearest filtered water faucet until you
can smell chlorine, then close the faucet.
DO NOT USE WATER FOR ABOUT 45
MINUTES.

Q After the 45 minutes, see step a to start a

backwash. The filter will complete this
backwash in about 35 minutes.

While the filter is backwashing, do step 15. Then

make the timer settings beginning on page 15.

|-|^ When the backwash is over, open filtered

' water faucets until chlorine odor is gone, then

close.

He TURN ON THE GAS (OR ELECTRIC)

* SUPPLY TO THE WATER HEATER AND

LIGHT THE PILOT.

14.

Advertising