Service hints, Condition what to check what to do – Sears KENMORE 1700 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

12.

13.

14.

Close top metal hinged cover and replace front plastic cover.

Plug in transformer.

Turn humidistat to Test" momentarily and check for media

wheel rotation. Reset humidistat according to outdoor tem­

perature as instructed on label and reinstall front cover. Unit
is back in operation.

SUMMER SHUT DOWN:

Unplug transformer, close saddle valve, dose bypass damper.
(CLEAN PER ABOVE AND LEAVE RESERVOIR EMPTY.) As a

reminder, you may want to put a tag or sticker on the unit indi­

cating it has been shut down for the summer and will require
start up in the fall.

FALL START UP:

Plug in transformer, open saddle valve, open bypass damper

and set humidistat to TEST position. Check tor proper water

level and media wheel operation. Set humidistat according to

outdoor temperature as instructed on label.

SERVICING THE FLOAT

It the humidifier has been overflowing, the float valve button

may be worn. This button wilt wear much like a faucet washer.

To service:

1.

Turn off water at saddle valve.

2.

Remove float from humidifier (pull out pivot pin).

3.

Service float as shown in illustration at left.

4.

Reinstall, turn on water at saddle valve and test float.

service hints

Frequently what seems to be a major problem can be solved very easily. Listed below are the common concerns with any humidifier.

Check the simple things first. Remove the front panel and see if there is a crusty, white lime build-up on the media pad. The lime build­
up won't hurt the humidifier, but will reduce its output. Low output might just mean your humidifier needs cleaning. While you're

checking for lime build-up, look to see if the media wheel is turning. If not, check the power supply.

CONDITION

WHAT TO CHECK

WHAT TO DO

Too little

1. Does humidifier need cleaning.

1. Clean humidifier and clean or replace media pad

Humidity

and reservoir liner.

2. Is media wheel rotating?

2. a. Clean or replace media pad.

b. Check to see if transformer is properly plugged in,
c. Inspect main fuse or circuit breaker.
d. Check to see if media motor is rotating.
e. Humidistat setting too low, turn knob clockwise

to increase humidity.

3. Humidistat setting.

3. Set tor proper outdoor temperature - lowest 24 hour

temperature.

4. Water to unit.

4. Turn on saddle valve and check for possible

obstruction in water line. Is water supply
connected?

5. Excessive air loss in house.

5. Close fireplace damper, seal around doors and

windows.

6. Is water level correct?

6. Adjust float.

7. Is damper open?

7. Slide damper out for winter operation.

Too much

1. Humidistat setting.

1. Turn knob counterclockwise to decrease humidity.

Humidity

2. Other humidification sources.

2. May be a temporary condition caused by moisture

from laundering, bathing, cooking, etc.

Humidifier

1. Is humidifier level?

1. Level unit.

Overflows

2. Float valve.

2. Service as shown in Fig. 25.

3. Air flow too high.

3. Adjust damper.

Humidifier

1. Mounting or plenum.

1. Tighten all fasteners.

Making Noise

2. Water pressure.

2. A slight sound is normal as water enters humidifier.

3. Media Wheel.

3. Check clearance of media wheel in reservoir.

Humidifier Motor

This is a normal condition

1. Turn knob on humidistat to minimum setting.

Comes On When

1. If heating season is over.

2. This is a normal condition since humidistat is

Furnace Isn't
Running

2. If heating season is just starting.

controlling humidifier.

1 0

Advertising