Kenmore 303.14601 FURNACE HUMIDIFIER MAINTENANCE

NOTE: APPLY THIS LABEL WHERE IT WILL BE EASILY SEEN AND SERVE AS A

REMINDER TO PERFORM THIS ROUTINE SERVICE.

Regular cleaning is necessary to keep the parts free of lime deposits.

Service every month during the heating season or more often depending on the water conditions.

1. Unplug transformer.

2. Close saddle valve.

3. Remove front plastic pane! and lift up top hinged cover.

4. Pull out pivot pin and remove float and float arm.

5. Lift out the media wheel and reservoir.

6. Pour contents of reservoir down the drain.

7. Clean lime from all parts using a solution of vinegar and water, detergent and water, or Sears All-Purpose

Humidifier Cleaner (Stock No. 42-14713).

8. Remove media pad from inside of wheel and dean thoroughly. Replace if necessary with Sears Stock No.

42-14603. IMPORTANT: Stretch new media lengthwise before placing in wheel.

9. If the reservoir has been overflowing, the operating float valve button may be worn. Remove the operating

float valve button, turn it over and reinsert (or replace after both surfaces are worn).

10. Reinstall reservoir, media wheel with pad, float, and pivot pin.

11 .Open saddle valve and check water level in reservoir. Adjust float as required.

12. Close top metal hinged cover and replace front plastic cover.

13. Plug in transformer.

14. Turn humidistat to "test" momentarily and check for media wheel rotation. Reset humidistat according to

outdoor temperature as instructed on label and reinstall front cover. Unit is back in operation.

Summer Shutdown

Unplug transformer, close saddle valve, close bypass damper.

CLEAN PER ABOVE AND LEAVE

RESERVOIR EMPTY.

(As a reminder you may want to put a tag or sticker on the unit indicating it

has been shut down for the summer and will require startup in the fall.)

Fall Startup

Plug in transformer, open saddle valve, open bypass damper and set humidistat to "test". Check for

proper water level and media wheel operation. Reset humidistat according to the outdoor temperature

as Instructed on label. Unit is back in operation.