Sears 390.306062 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

AWARNING

Hazardous fiimes. Follow cement manu-

fecturer’s instractions. Use PVC cement only in a well
ventilated place away ih>m lire or flame.

11. Put clamp on adapter, leave loose. Motmt check valve in

adapter; thread assembly into tee.

12. Slip pump into check valve. Tighten clamp.

Reducer Bushing (2 Supplied)

Main Pump Discharge Pipe

Check Valve to Prevent

Recirculation into Sump

Figure 2B — Installation Diagram

13. Make sure battery is fully charged; then check operation

by disconnecting power to primary sump pump and fill­
ing sump until Backup Sump Pump starts. Run Backup
Pump through one complete cycle.

ELECTRICAL CONNECTIONS

A

warding

Hazardous voltage. Can cause serious or

fatal electrical shock. Review safety instructions, Page 2, be­
fore operating charger.

If your outlet is not grounded, install a copper wire (at least

14 gauge) from the outlet box to a cold water pipe. Use

ground clamp on pipe. BE SURE that the cold water pipe
used has metal continuity to electrical ground. Battery
charger is double insulated. DO NOT modify cord or plug.

CHARGER/BATTERY INSTALLATION

NOTICE: Alarm will sound when charger is first connected
to battery. Press ALARM TEST/RESET button on charger. If
alarm continues to sound, discoruiect one charger lead from

-the battery and reconnect it. Press ALARM TEST/RESET

again; alarm will stop sounding.

1. Connect charger as shown in Figure 3.

A. Connect Positive (-H) lead from charger to positive battery

post.

B. Connect Negative (-) lead from charger to negative bat­

tery post.

C. Third lead from charger is factory connected to lead from

pump motor/float switch.

NOTICE: If charger is connected backwards, pump will
not operate properly, battery will not charge.

2. Plug in power cord to a 115-125 Volt AC outlet delivering

at least 2 amps. Do not use a switch controlled outlet
Mark circaait in main power panel “Backup sump pump
power supply; do not turn ofiT.

3. With charger properly connected and plugged in, the

panel on the front of the charger will appear as in one of
the following:

A. If battery is dead, charger will supply about 10 amps

power (see Figure 4A).

B. If battery is near full charge, charger will deliver about

5 amps power (see Figure 4B).

Figure 3 - Wiring Connections

DC

CHARGED

■'j 2 4 6 8 \o 12

■ ■ ■ ■ ■ ■

^CHARGE COMPLETE

CHARGING

CHARGED I

2

4 le 8

10

12

■CHARGE COMPLETE

B. K

c.

1413 1194

Figure 4 — Battery Backup Control Panel

A. Battery depleted - charging current 10 amps.

B. Battery nearly charged - current about 5 amps.

C. Charge complete - current 0 amps, LED lights up.