13. Reinstall battery clamps;

A. Black switch wire clamps to positive battery terminal.

B. Black pump wire clamps to negative battery terminal.

NOTICE: DO NOT reverse terminal connections.

14. Tum pump upside down; unclip and remove screen. Do

not remove screw-mounted bottom plate. lift switch to
momentarily "bump” pump. Check for correct operation
and rotation (ptimp must rotate counter-clockwise
when looking at end of shaft - Figure 8). If not, reverse
wires to battery and recheck.

15. Replace screen.

16. Plug in charger to wall outlet.

17. Fill sump with water and check switch action. Adjust

tether if necessary.

A CAUTION lix) NCyr

test run pump for more than

5 seconds without

water

in it. Running pump dry for

extended periods could damage pump and voids war­
ranty.

Craftsman Battery Backup Sump Pump

Model 390.306062

Negative Battery Clamp

Positive Battery Clamp

CZZ]

цицицуицициишшг

1412 1194

REPAIR PARTS LIST

Key No.

Part No.

Part Description

1

PS217-5E

Switch Assembly #

2

PS17^1

Pump Complete***

3

CC0030-13

Cord Clamp

4

U17-1148

Fuse Holder

5

U17-1149

15-Amp Time-Delay Fuse (2 supplied t)

6A

**

Wire Terminal (4 Req.)

6B

**

Battery Terminal Clamps (2 Req.)

*

PS17-100

Battery Case (includes strap and strap brackets)

7

PS117-77A

Charger***

8

PS22-1

Check Valve

9

**

Hose Clamp Г min. - 2“ max. S.S.

10

PS78-3P

Pipe Adapter

11

U78-846P

Tee 1-1/2

X

1-1/2 x 1-1/4 PVC

12

U78-876P

Reducer Bushing (2 Req.)

# When ordering, also order Key Nos. 4 (Fuse Holder) and 5 (Fuse) required for installation.

* Not illustrated.

** Standard Hardware Item; purchase locally.

"* No component parts available for pump or battery charger,