C. If battery is fully charged, charging current will be 0

anrps and green LED lamp will be lighted (see Figure
40.

4. The charger is equipped with a self-resetting circuit

breaker whi<^ protects it from temporary overloads. In
case of an overload, the circuit breaker open. It au­
tomatically resets after a short cooklown period. In some

conditions where the overload is extended the breaker
will cycle, repeating the open/reset process indefinitely.
When this happens, normally the charger will emit a click­
ing soimd as the breaker opens and resets.

NOTICE: If the clicking sound continues for more than

30 minutes or so, check for reversed charger connections

to the battery and for shorted cells in the battery.

BATTERY MAINTENANCE

NOTICE: To protect battery case from chipping and goug-

ing_do not let battery sit on concrete floor. Install battery on

a shelf or protective pad (plywood, 2x4s, etc.). Always in­
stall battery in a dry location that is protected from flooding.

Every three months, check battery as follows to maintain
battery in best condition:

1. Unplug battery charger.

2. On batteries with removable top caps, measure specific

gravity of the electrolyte. Use a hydrometer (available at
auto parts stores). If the specific gravity of any cell is less
than 1.225 or if there is more than .050 variation between
cells, replace the battery.

3. Check electrolyte level and refill as needed.

4. Check battery terminals and clamps for tightness and cor­

— -rosion-.'Glean and tighten as needed.

5. Plug in battery charger.

TROUBLESHOOTING

Pump won’t run.

1. Check all connections.

2. Check for low or defective battery.

3. Check that automatic switch is free to swing up and

down.

4. Blown fuse in switch circuit. Unplug pump and check to

see if impeller is free to turn. If impeller is locked, remove
the housing around the impeller and remove the ob­
struction. Reassemble pump and reconnect. Replace fuse.

Motor hums but pump won’t run:

1. Check for low or defective battery.

Pump runs but pumps very little or no water:

1. Make sure a check valve is installed and functioning be­

tween primary pump discharge and Backup Sump Pump
tee.

2. Check for obstruction in discharge pipe.

3. Discharge pipe length and/or height exceeds capacity of

pump. See Table I, Page 4, for pump capacity.

4. Check for low or defective battery.

Pump cycles too frequently:

1. Tether length too short on automatic float switch. Make

sure that tether is at least 2"; see Figure 2.

2. Main check valve located between discharge of primary

ptimp and the Backup Sump Pump tee or check valve not
installed or working properly. Install or repair as required.

SWITCH REPLACEMENT

1. Unplug battery charger from wall outlet.

2. Discormect both battery clamps from battery terminals.

3. Unbolt black switch wire from battery clamp.

4. Unplug fuse holder in white wire; save fuse.

5. Make a note of tether length (see Figure 2) before loos­

ening cord clamp.

6. Remove cord from cord clamp and replace with new

cord. Make sure tether length is the same as the old
switch’s tether.

7. Strip insulation off of white wire on new switch, leaving

3/8" bare wire exposed at the wire end (see Figure 5).

8. Insert stripped wire end in small end of fuse holder half;

crimp holder onto wire and check crimp for tightness
(Figure 6).

NOTICE: Be sure that fuse holder half which you are in­

stalling will mate with fuse holder half on pump wire.

9. Insert fuse into holder and snap halves of housing to­

gether (Figure 7).

10. Remount block on band and cord clamp assembly on

pump.

11. Strip black switch wire back 3/8" from end of wire. Crimp

wire terminal onto end of wire and check for tightness.

12. Bolt black switch wire onto battery terminal clamp.

►I и-3/в"

Figure 5

—о=ет

Figure 6

Figure 7

Figure 8