Ducting Infcxmotion

The ventilation system is designed to capture both

cooking fumes and smoke while grilling. If the system

does not, these are some ducting installation situations

to check:

• 6" diameter round or 3H" x 10" rectangular duct­

ing should be used. Note: 5" diameter round

ducting may be used if the duct length is 10' or less.

No more than three 90® elbows should be used.

Distance between elbows should be at least 18".

• There should be a minimum clearance of 6" for

cooktop installed near a side wall.

If there is not an obvious improper installation, there

may be a concealed problem such as a pinched joint,

obstruction in the pipe, etc. Installation is the respon­

sibility of the installer and questions should be ad­

dressed first by the installer. The installer should very

carefully check the ducting installation instructions.

Recommended Kenmore wall cap should be used.

Make sure damper moves freely when ventilation

system is operating.