Lincoln LN-7 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Assembly and Installation

The Lincoln Electric Company

Cleveland, Ohio 44117

Sec. J2.2.3 Continued

Gun Cable: LN-7 to Gun

Lay the cable out straight. Insert the connector on the

welding conductor cable into the brass block on the front
of the LN-7. Make sure it is all the way in and tighten the
locking screw with a 3/16” Allen Wrench. Keep this con­
nection clean and bright. Insert the control cable polarized

plug into the receptacle below the nameplate.

Linconditioner'i’M Guns

^

For locations where smoke accumulation is a problem

and conventional exhaust systems are ineffective, the

available smoke removal type Innershield guns and vacuum
units can be used. Instructions are shipped with the
equipment.

April 1974

-8-