Example
The following example shows the settings on JC, JD, JE and JF
where RS-422/485 port 1 is terminated on RTS ± and TxD
±,
the RS-422/485 port 2 is set for bias/termination on RTS
±,
TxD
±, CTS ±, and RxD ±, the RS-422/485 port 3 is not
terminated, and port 4 is set for RS-232 on jumper block JB
and therefore should not be terminated

JC

PORT 1

Jumper Legend

1 = CTS terminator

and bias

2 = CTS terminator
and

bias

3 = RxD terminator

and bias

4 = RxD terminator

and bias

5 = TxD terminator
6 = RTS terminator

JC1

JC2

JC3

JC4

JC5

JC6

JD

PORT 2

JD1

JD2

JD3

JD4

JD5

JD6

JE

PORT 3

JE1

JE2

JE3

JE4

JE5

JE6

JF

PORT 4

JF1

JF2

JF3

JF4

JF5

JF6

Technical Notes:
1. For full duplex and multi-drop slave you can jumper

positions 1, 2, 3, 4, 5, and 6, on the appropriate jumper
block (JC, JD, JE or JF) if you want them terminated.

2. For RS-232 ports do not jumper positions 1, 2, 3, 4, 5, and

6, on the appropriate jumper block (JC, JD, JE or JF).