Example
The following example shows the settings on JA, JB, JC and JD
where port 1 is terminated on RTS ± and TxD
±, the
RS-422/485 port 2 is set for bias/termination on RTS
±, TxD ±,
CTS
±, and RxD ±, the RS-422/485 port 3 is not terminated,
and port 4 is set for RS-232 and therefore should not be
terminated

JA

1

2

3

4

5

6

7

8

JB

1

2

3

4

5

6

7

8

JC

1

2

3

4

5

6

7

8

JD

1

2

3

4

5

6

7

8

Port 1

Port 2

Port 3

Port 4

Jumper Legend

1 = RS-232/RS-422/485

select

2 = RS-422/485 half

duplex mode control

3 = RTS +/- termination
4 = TxD +/- termination
5 = CTS +/- termination
6 = CTS +/- termination
7 = RxD +/- termination
8 = RxD +/- termination

Technical Notes:
1. For full duplex, half duplex and multi-drop slave you can

jumper position 2 on the jumper block.

2. For RS-232 port jumper position 1 on the jumper block.