Connecting the external power supply – CyberResearch UCERB 24 User Manual

Page 15

Advertising
background image

Each DIP switch sets the configuration of one relay group. The DIP switch labeled

A

configures relays 1

to 8, the switch labeled

B

configures relays 9 to 16, the switch labeled

CL

configures relays 17 to 20, and

the switch labeled

CH

configures relays 21 to 24 (

).

Figure 2-2

Figure 2-2. Typical board switch

Configures

9-16

relays

Configures relays17-20
Configures relays21-24

CL
CH

A
B

Port A consists of relays 1 through 8, Port B consists of relays 9 through 16, Port CL consists of relays 17
through 20, and Port CH consists of relays 21 through 24.

Remove from the enclosure to access the on-board switches
To change the configuration of a switch, you must first remove the

UCERB 24 from the enclosure.

Relay control logic polarity

Configure the

Invert/non-invert

switch (S1) to set the relay control logic polarity for each relay bank for

invert or non-invert. By default, this switch is shipped with all banks configured for non-inverted logic, as
shown in

.

Figure 2-3

Figure 2-3. Relay logic switch S1

NON-INVERT

INVERT

S1

CL
CH

A
B

ƒ

NON-INVERT

mode: when "0" is written or read back via the USB bus, the relays are not energized.

ƒ

INVERT

mode: when "0" is written or read back via the USB bus, the relays are energized.

Switch settings for polarity can be read back via software through the USB bus. Switch settings for S1 do
not affect the power-on condition.

Relay power-on state

Configure the

Pull-up/pull-down

switch (S2) to set the state of each relay bank at power-up. By default,

this product is shipped with the switch for all banks configured for pull-down (relays inactive at power
up), as shown in

. Switch settings can be read back via software through the USB bus.

Figure 2-4

Figure 2-4. Resistor pull-up/down switch S2

S2

PULL UP

PULL DOWN

CL
CH

A
B

ƒ

PULL-UP

: the relays are put into an energized state at power-up, regardless of the state of switch S1

ƒ

PULL-DOWN

: the relays are put into a non-energized state at power-up.

Connecting the external power supply

Power to the

UCERB 24 is provided with the 9 V, 3 A external power supply. You must connect the

the external power supply before connecting the USB connector to the

UCERB 24.

To connect the power supply to your

UCERB 24, do the following:

1.

2.

Connect the external power cord to the power connector labeled

POWER IN

on the

UCERB 24

enclosure (

PWR IN

on the board). Refer to

for the location of this connector.

Figure 3-1

Plug the AC adapter into a power outlet.

CyberResearch

®

Digital I/O

UCERB 24

CyberResearch, Inc.

7

25 Business Park Drive

P: (203) 483-8815; F: (203) 483-9024

Branford, CT USA

www.cyberresearch.com

Advertising