Chapter 4

Specifications

Typical for 25 °C unless otherwise specified.
Specifications in italic text
are guaranteed by design.

Output specifications

Table 4-1. Output specifications

Number of relays

24

Relay configuration

2 banks of 8 and 2 banks of 4

Contact configuration 24 Form C (SPDT) Normally Open, Normally Closed and Common available at screw

terminals

Contact rating

6 A @ 240 VAC or 28 VDC resistive

Contact resistance

100 milliohms max (initial value)

Operate time

10 milliseconds max

Release time

5 milliseconds max

Vibration

10 to 55 Hz (amplitude 1.5 mm)

Shock

10 G (11 milliseconds)

Dielectric isolation
(between relay open
contact)

300 VAC, 50/60 Hz (1 minute)

Dielectric isolation
(between PCB output
lines)

500VAC, 50/60 Hz (1 minute)

Life expectancy

10 million mechanical operations, min

S2 =
pull-up

Energized. NO in contact with Common

Power on
state

S2 =
pull-
down

Not energized. NC in contact to Common

Relay control logic
polarity

User-configurable per bank via switch S1 for invert or non-invert (default). Switch settings
for polarity can be read back via software through the USB bus. Switch settings do not
affect the power on condition. Non-invert mode, when "0" is written or read back via the
USB bus, relays are not energized. Invert mode, when "0" is written or read back via the
USB bus, relays are energized.

Pull-up / pull-down

User-configurable per bank via switch S2 for pull-down (default) or pull-up. Switch
Settings can be read back via software. Pull-down will put the relays in non-energized
mode on power up. Pull-up will put the relays in energized mode on power up.

CyberResearch

®

Digital I/O

UCERB 24

CyberResearch, Inc.

19

25 Business Park Drive

P: (203) 483-8815; F: (203) 483-9024

Branford, CT USA

www.cyberresearch.com

Advertising