All three door panels are removable for easier access to the interior of the console during
installation and maintenance.
To remove door panel:
1. Unlock key-lock.
2. Open door.
3. Push down on spring-loaded pin hinge.
4. Remove panel.
To install door panel, reverse the above procedure.

4 . 2 . 3 . V

E N T I N G

It is necessary to vent hot exhaust air from console to the outside of the building.
1. Connect a eight-inch inner-diameter, flexible, fireproof ducting material to exhaust duct

(Item 1 in Figure A-2) on top of lamphouse.

2. Ensure that there are no obstructions in ducting, and that air intake openings of console

are unobstructed.

If ozone-free lamps are used, a short, vertical exhaust stack may be used, provided local

codes do not require the exhaust to be vented directly outside.

External exhaust air extraction is required. Minimum and maximum exhaust airflow
requirements for all SLC series models are shown in Figure 4-3.

Model Minimum

Exhaust

(ft

3

/min) Maximum

Exhaust

(ft

3

/min)

SLC 20

300

400

SLC 30

350

450

SLC 40

450

550

SLC 45, SLC 45R

550

750

SLC 70

750

900

Figure 4-3: Minimum and Maximum Exhaust Airflow Requirements for SLC Consoles