Christie Digital Systems XENON CONSOLE User Manual

Page 21

Advertising
background image

5

CHRISTIE DIGITAL SYSTEMS

5-1

August 7, 2003

5 .

A L I G N M E N T A N D C H E C K O U T P R O C E D U R E S

5.1. M

E C H A N I C A L

A

L I G N M E N T

When installing an SLC console equipped for 35/70 mm operation, be certain
that the optical bench assembly is in the correct sliding position: FORWARD

for 70 mm, to the REAR for 35 mm. Contact Christie for more information or
for assistance.

All SLC Consoles are optically aligned at the factory. The optical bench or plenum assembly
is aligned with an optical laser alignment tool. At installation, if not already mounted, the

projector must subsequently be mechanically aligned to the console snood. This is done by

adjusting the jackscrews on the projector mounting bracket (Up/Down, Left/Right). (See
Item 14 in Figure A-2.)
A satisfactory mechanical alignment can readily be obtained without the use of any special
tools.

5.2. I

N S T A L L A T I O N O F

X

E N O N

L

A M P

WARNING

Authorized protective clothing must be worn when protective cover is
removed from lamp.

1. Turn off all AC power.
2. Open top door on the operating (right) side of console.
3. Remove plenum access cover.
4. Verify that lamp model number and rating correspond to the rating on the console

nameplate or lamp rating sticker.

5. Remove lamp from package.

WARNING

Do not touch the quartz body of the lamp with bare hands at any time.
Do not apply any bending or twisting force to the quartz body of the

lamp.

Advertising