ELECTRICAL OPERATION HAZARD
Failure to follow this caution will result in equipment damage
or improper operation.
Improper wiring of the ABCD connector will cause the
Infinity Control™ to operate improperly. Check to make sure
all wiring is correct before proceeding with installation or
turning on power.

9. Push any excess wire into the wall. Seal hole in wall to prevent

any air leaks. Leaks can affect operation.

10. Attach Infinity Control™ to the mounting plastic by lining up

the plastic guides on the back of the control with the opening
on the mounting plastic and push on.

11. Perform installation of all other system equipment (i.e. hu-

midifier, ventilator, UV lights, etc.)

12. Turn on power to equipment.

EQUIPMENT WIRING DIAGRAMS:

See wiring diagram Figs. 12, 13 and 14.

NOTE:

For other applications not listed, refer to the Network

Interface Module (NIM) Installation Instructions.

See wiring diagram figure 12 for a Typical Four-Wire Connection
Diagram, which includes an Infinity indoor communicating fur-
nace or FE fan coil with a 2-speed Puron® communicating outdoor
unit. No additional OAT (outdoor air temperature) sensor is
required because the Infinity Control will use the temperature
sensor inside the 2-speed unit.

See wiring diagram figure 13 for a Typical Connection Diagram,
which includes an Infinity indoor communicating furnace or FE
fan coil, with a 1-speed air conditioning unit (non-communicating
outdoor). An Outdoor Air Temperature sensor may be installed
(not required) at the indoor furnace or fan coil OAT terminals.
When OAT is applied, the Infinity System will provide full system
features and benefits.

See wiring diagram Fig. 14 for a Typical Connection Diagram for
FE fan coil with a 1-speed heat pump (using non-communicating
outdoor unit). When OAT is applied, the Infinity System will
provide full system features and benenfits.

HUMIDIFIER CONNECTION — A 24vac bypass or fan
powered humidifier may be installed.

NOTE:

Do Not Use a traditional humidistat to control humidifier

operation. If a humidifier is installed, let the Infinity System
control humidifier operation.

Bypass Humidifiers — A bypass humidifier should be wired
directly to the furnace or fan coil HUM and 24vac COM terminals.
The Infinity Control will automatically energize the HUM output
during a call for humidification.

Fan Powered Humidifiers — Most fan powered humidifiers
produce internal 24vac in order to energize upon a switch or
contact closure. For this application, a 24vac N.O. Isolation Relay
(DPST) MUST be used to prevent mixing the internal humidifier
power with the indoor equipment transformer. Applying 24vac
isolation relay coil to furnace or fan coil HUM and COM terminals
will allow the Infinity Control to automatically energize the HUM
output during a call for humidification. The N.O. relay contacts
will be used to energize the humidifier. See fan powered humidi-
fier installation instructions for more details.

Fig. 9—Decorative Backplate Assembly

A03192

Fig. 10—4–Wire ABCD Connector

A03193

A

B

C

D

Fig. 11—Functional Overview

A03194

HOLD

COOL

HEAT

SCHEDULE

VACATION

PROGRAM

SCROLL

BASIC

ADVANCED

SETUPS

Schedule

to program

temperature

schedule

Vacation

to start/end

vacation

Basic

to set time,

humidity

Advanced

for all other

settings

Scroll

up & down

Fan Button

Display Screen
(LCD)

Right-Side
Button

Heat Button

Cool Button

Temperature
(+/-) Button

System
On/Off Button

Basic & Advanced
Setup Buttons

Flip Down
Door

Left-Side
Button

Humidity/OAT
Button

Hold
Button

Time (+/-)
Button

Schedule & Vacation
Program Buttons

Up/Down
Scroll Buttons

A

B

C

D

A

B

C

D

User Interface

Green

Yellow

White

Red

OAT

Optional Remote

Room Sensor

HUM

COM
24V

Humidifier

Connection

S2

S1

A

B

C

D

ABCD

Connections

2-Spd. AC or HP

Green

Yellow

White

Red

OAT

Sensor

(Optional)

Variable-Speed

Furnace/ Fan Coil

Fig. 12—Universal Four-Wire Connection Diagram

A03146

4

Advertising