Fig. 17—selecting electric heater, Fig. 19—equipment summary – Carrier Infinity SYSTXCCUID01 User Manual

Page 6

Advertising
background image

NOTE:

Range of electric heaters available is limited by the model

of the fan coil installed. The Infinity Control™ will not allow an
electric heater size that is not supported by the installed fan coil.

SECTION 4 — SELECTING ACCESSORIES

Once the indoor and outdoor equipment have been found or
entered, the following screens will appear allowing the Installer to
select the AIR FILTER TYPE; HUMIDIFIER INSTALLED; and
UV LIGHTS INSTALLED

″ (See Fig. 18). Use either Time or

Temp +/- buttons to make the appropriate selections in the
highlighted area on the display screen. Press right-side button to
continue (or advance) to the next screen.

AIR FILTER TYPE— This accessory screen will appear first.
The installer will need to enter the type of filter (MEDIA, EAC, or
both). See Table 1 and make a selection using Time or Temp +/-
button, then press right-side button to continue.

HUMIDIFIER TYPE — This will appear after the Air Filter
Type screen. Select whether a humidifier is installed on the
system, YES or NO, then press the right-side button to continue.

UV LIGHTS INSTALLED— This screen will appear to select
whether UV lights are installed on the system, select YES or NO,
then press the right side button to continue.

SECTION 5 — EQUIPMENT SUMMARY

The

EQUIPMENT SUMMARY″ screen will appear after Ac-

cessories have been selected. This screen will give a summary of
all equipment automatically found or manually selected. If a wrong
selection was made, press left-side button (BACK selection) to go
back to that particular screen and make changes. When everything
is OK, press right-side button again to continue. (See figure 19)

The

SETUP COMPLETE! SAVE ALL SELECTIONS?

screen will appear after Equipment Summary. To Save All
Selections press (YES) right-side button. Pressing the left-side
button (NO selection) will return to the Equipment Summary
screen where you can back up to any of the equipment selection

screens and perform changes. After selecting YES, the initial
power up sequence of the new Infinity Control™ is complete. The
User Interface screen will now display normal operating mode.
Also, after selecting YES, if the filter type is not an EAC, the
indoor unit will operate the blower for one minute to do a system
static pressure check.

QUICK START

For first time installers, Quick Start will allow you to start up the
Infinity System before you have the chance to learn all the details
of system operation. However, for the best possible comfort and
operation we recommend that you refer to the Infinity Control™
Homeowner’s Guide.

SET DAY, TIME & DESIRED HUMIDITY

1. Flip down the door at the base of the Infinity Control™ and

press the BASIC button.

2. Adjust the highlighted HOUR setting using the TIME (+/−)

button.

3. Press SCROLL button (down) to highlight MINUTE.

4. Adjust the MINUTE setting using the TIME (+/−) button.

5. Press SCROLL button (down) to highlight DAY.

6. Adjust the current DAY setting using the TIME (+/−) button.

7. Press SCROLL button (down) to highlight HUMIDITY.

8. Press the red HEAT button to select heating humidity.

9. Adjust desired heating humidity level using either (+/−)

button.

10. Press the blue COOL button to select cooling humidity.

11. Adjust

the

desired

cooling

humidity

level

using

either(+/−)button.

12. To exit press BASIC button or close door.

OVERRIDE HEATING SCHEDULE

1. Press the red HEAT button. Heating mode is confirmed when

the red LED next to the red HEAT button is lit.

2. Use the TEMP (+/−) button to select your desired heating

temperature.

3. The default time for temporarily overriding the temperature

schedule is 2:00 HRS as indicated by the text on the lower left.

NOTE:

Override time will not appear if programming has been

turned off.

4. You can change the temporarily override time in 15-minute

increments by pressing the TIME (+/−) button until the
desired override time is selected, or press the HOLD button
anytime to override the schedule indefinitely.

OVERRIDE COOLING SCHEDULE

1. Press the blue COOL button. Cooling mode is confirmed

when the blue LED next to the COOL button is lit.

2. Use the TEMP (+/−) button to select your desired cooling

temperature.

3. The default time for temporarily overriding the temperature

schedule is 2:00 HRS as indicated by the text on the lower left.

Fig. 17—Selecting Electric Heater

A03197

ELECTRIC HEATER

NOT IDENTIFIED

ENTER SIZE:

5 KW

NONE, 5,10,15 KW

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

INSTALLED FILTER

MENU SELECTION

1 Inch to 4 inch media

MEDIA

High voltage EAC

EAC

High voltage EAC + 1 to 4 inch media

MEDIA + EAC

Table 1 — Filter Selection

Fig. 18—Accessories — UV Lights

A03198

ACCESSORIES

HUMIDIFIER
INSTALLED?

YES

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

ACCESSORIES

U.V. LIGHTS
INSTALLED?

YES

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

ACCESSORIES

AIR FILTER TYPE:
EAC

EAC

MEDIA
MEDIA + EAC

PRESS +/- TO MAKE

SELECTION

CONTINUE

AIR FILTER MEDIA TYPE

HUMIDIFIER INSTALLED?

U.V. LIGHTS INSTALLED?

Fig. 19—Equipment Summary

A03199

EQUIPMENT SUMMARY

FURNACE 58MVP0100-12
AC 38TDB036300
FILTER EAC
HUMIDIFIER YES
UV LIGHTS YES

BACK EXIT

SETUP

COMPLETE!

SAVE

ALL SELECTIONS?

NO YES

6